The NDT community has discussed about effective film replacement by Computed Radiography (CR) and the new Digital Detector Arrays (DDA), also known as flat panel detectors, since more than 10 years. Several standards were published by CEN, ASTM and ASME to support the application of phosphor imaging plates in lieu of X-ray film in the year 2005. One of the key concepts is the usage of signal/no...
The measurement of stereotactic radiosurgical dose distributions requires an integrating, high-resolution dosimeter capable of providing a spatial map of absorbed dose. Although radiographic film is an accessible dosimeter fulfilling these criteria, for larger radiotherapy photon fields the sensitivity of film emulsion exhibits significant dependencies on both depth in phantom and field size. W...
OBJECTIVE The objective of this study was to compare the technical errors of intraoral radiographs exposed on film v photostimulable phosphor (PSP) plates. METHODS The intraoral radiographic images exposed on phantoms from preclinical practical exams of dental and dental hygiene students were used. Each exam consisted of 10 designated periapical and bitewing views. A total of 107 film sets an...
The NDT community discusses about effective film replacement by Computed Radiography (CR) and Digital Detector Arrays (DDA), also known as flat panel detectors, since more than 10 years. Several standards were published by CEN, ASTM and ASME to support the application of phosphor imaging plates in lieu of X-ray film in the year 2005. The European Community funds the project FilmFree, which supp...
Current classification criteria for axial spondyloarthritis (axSpA) provide for the inclusion of patients with a wide range of presentations and manifestations. While not considered a formal subclassification, patients are often divided into radiographic or nonradiographic axSpA based on the presence or absence of radiographic sacroiliitis. This review will focus on nonradiographic axSpA and wi...
Introduction. The purpose of this study was to determine the interand intra-observer reliability of a clinical radiographic scale for hallux rigidus. Methods. A total of 80 patients were retrospectively selected from the patient population of two foot and ankle orthopaedic surgeons. Each corresponding series of radiographic images (weightbearing anteroposterior, weight-bearing lateral, and obli...
Radiographic film dosimetry provides fast, convenient 2-D dose distributions, but is challenged by the dependence of film response on scatter conditions (i.e., energy dependence). Verification of delivered dose in the surface buildup region is important for intensity modulated radiation therapy (IMRT) when volumes of interest encroach on these regions (e.g., head/neck, breast). The current work...