نتایج جستجو برای: rectal retractor prostate cancer radiotherapy rectum
تعداد نتایج: 988414 فیلتر نتایج به سال:
We present a salutary lesson learned from three cases with significant complications that followed anorectal intervention in the presence of radiation proctitis due to prior radiotherapy for adenocarcinoma of the prostate. After apparent routine rubber band ligation for painful haemorrhoids, one patient developed a colo-cutaneous fistula. Following laser coagulation for radiation proctitis, one...
BACKGROUND Surgery plus adjuvant radiotherapy is standard care for locally advanced prostate cancer (stage pT3R1). Intraoperative low-energy photon radiotherapy offers several advantages over external beam radiotherapy, and several systems are now available for its delivery, using spherical applicators, which require only limited shielding. The aim of this study was to evaluate the feasibility ...
Abstract Introduction We report a case of small cell carcinoma the prostate (SCCP) which is rare, high-grade malignant neoplasm accounting for 1% all cancers (CPa). Case Presentation A 56-year-old male patient initially presented to primary care with six-month history frequency, nocturia and pain in perineal region when seated. positive family-history CPa was noted, serum PSA 11.58, rectal exam...
The extent of ADP-ribosylation in rectal cancer was compared to that of the corresponding normal rectal tissue. Twenty rectal tissue fragments were collected during surgery from patients diagnosed as having rectal cancer on the basis of pathology results. The levels of ADP-ribosylation in rectum cancer tissue samples (95.9 +/- 22.1 nmol/ml) was significantly higher than in normal tissues (11.4 ...
Introduction: Recently, magnetic resonance spectroscopic imaging (MRSI), as a functional imaging method, has been used for clinical target volume definition. In this study, we used this method to define the target volume in prostate radiotherapy. Material and Method: In this study, we used images of 20 prostate cancer cases. MRSI and MRI images were fused with CT images. Then, treatment plannin...
BACKGROUND Kilovoltage Intrafraction Monitoring (KIM) is a method which determines the three-dimensional position of the prostate from two-dimensional kilovoltage (kV) projections taken during linac based radiotherapy treatment with real-time feedback. Rectal displacement devices (RDDs) allow for improved rectal dosimetry during prostate cancer treatment. This study used KIM to perform a prelim...
In the present study, we aimed to evaluate effects of bladder filling on dose-volume distributions for bladder, rectum, planning target volume (PTV), and prostate in radiation therapy of prostate cancer. Patients (n = 21) were scanned with a full bladder, and after 1 hour, having been allowed to void, with an empty bladder. Radiotherapy plans were generated using a four-field box technique and ...
PURPOSE To evaluate intensity-modulated radiation therapy (IMRT) as an alternative to conformal radiotherapy (CRT) or 4-field box boost (4FB) in women with gynecologic malignancies who are unsuitable for brachytherapy for technical or medical reasons. METHODS Dosimetric and toxicity information was analyzed for 12 patients with cervical (8), endometrial (2) or vaginal (2) cancer previously tr...
The aim of this study was to observe the relationship between dose-volume histogram (DVH) parameters and rectal late side effects (LSE) in computed tomography (CT)-based brachytherapy (BT) for patients with locally advanced cervical cancer. In total, 144 cervical cancer patients received external beam radiotherapy and CT-based BT. The data from 111 survival cases with pelvic local control (LC) ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید