نتایج جستجو برای: spect slit slat collimator

تعداد نتایج: 23367  

Journal: :Medical physics 2015
Karen Van Audenhaege Roel Van Holen Christian Vanhove Stefaan Vandenberghe

PURPOSE Brain single photon emission computed tomography (SPECT) imaging is an important clinical tool, with unique tracers for studying neurological diseases. Nowadays, most commercial SPECT systems are combined with x-ray computed tomography (CT) in so-called SPECT/CT systems to obtain an anatomical background for the functional information. However, while CT images have a high spatial resolu...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 1992
T F Lang B H Hasegawa S C Liew J K Brown S C Blankespoor S M Reilly E L Gingold C E Cann

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an ar...

Journal: :Applied optics 2012
William F Grainger Roser Juanola-Parramon Peter A R Ade Matt Griffin Flo Liggins Enzo Pascale Giorgio Savini Bruce Swinyard

A laboratory prototype spectral-spatial interferometer has been constructed to demonstrate the feasibility of the double-Fourier technique at far infrared (FIR) wavelengths (0.15-1 THz). It is planned to use this demonstrator to investigate and validate important design features and data-processing methods for future astronomical FIR interferometer instruments. In building this prototype, we ha...

2015
Asuka Mizutani Ichiro Matsunari Masato Kobayashi Kodai Nishi Wataru Fujita Yoshiharu Miyazaki Stephan G Nekolla Keiichi Kawai

BACKGROUND The aims of this study were (1) to evaluate the impact of injection dose, post-reconstruction filtering, and collimator choice on image quality of myocardial perfusion single-photon emission computed tomography (SPECT) using cadmium-zinc telluride (CZT) detectors and (2) to determine how these factors affect measured infarct size in the in vivo rat. METHODS Twenty-four healthy and ...

Journal: :Genetics 1987
I A Boussy M G Kidwell

The dramatic latitudinal cline in P-M hybrid dysgenesis characteristics along the east coast of Australia is not smooth. Tests of recent collections of Drosophila melanogaster from the southeastern coast define the previously described cline as comprising three discrete, apparently contiguous regions of P, Q and M phenotypes, respectively. Northern populations from Cairns (16.9 degrees SLat) to...

Journal: :Medical physics 2015
Francisco Pino Nuria Roé Pablo Aguiar Carles Falcon Domènec Ros Javier Pavía

PURPOSE Single photon emission computed tomography (SPECT) has become an important noninvasive imaging technique in small-animal research. Due to the high resolution required in small-animal SPECT systems, the spatially variant system response needs to be included in the reconstruction algorithm. Accurate modeling of the system response should result in a major improvement in the quality of rec...

Introduction:It is well-recognized that collimator-detector response (CDR) is the main image blurring factor in SPECT.  In this research, we compensated the images for CDR in molecular SPECT by using STIR reconstruction framework. Methods: To assess resolution recovery capability of the STIR, a phantom containing five point sources along with a micro Derenzo p...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید