Journal: :Journal of chromatography. B, Analytical technologies in the biomedical and life sciences 2005
Joon-Soo Sim Gyungjin Jun Toshihiko Toida So Yean Cho Don Woong Choi Seung-Yeup Chang Robert J Linhardt Yeong Shik Kim

We performed the quantitative analysis of chondroitin sulfate (CS) obtained from raw materials and various pharmaceutical preparations. To quantify CS content in raw materials and in an ophthalmic solution, each test sample and the authentic CS were first digested by chondroitinase ABC. The CS disaccharides produced were analyzed by strong anion-exchange high-performance liquid chromatography (...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2002
Mitsuhiro Wada Chieko Morinaka Toshihiko Ikenaga Naotaka Kuroda Kenichiro Nakashima

An HPLC method with fluorescence detection for the determination of nitric oxide (NO) in cultivated plant cells (Agave pacifica, Agavaceae) was developed. NO was derivatized in situ with 2,3-diaminonaphthalene (DAN) as a labeling reagent and converted to 1(H)-naphthotriazole. The maximum peak height of the derivative was observed by incubation for 3 h at 25 degrees C with 0.2 mM DAN. Excess rea...

2016
Jie Cheng Xiao-Ou Su Shi Wang Yiping Zhao

Combining surface-enhanced Raman spectroscopy (SERS) of aggregated graphene oxide/gold nanoparticle hybrids with immunomagnetic bead sample preparation method, a highly sensitive strategy to determine the clenbuterol content in animal urine was developed. Based on a linear calibration curve of the SERS characteristic peak intensity of clenbuterol at Δv = 1474 cm(-1) versus the spiked clenbutero...

Journal: :European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies 1994
E G Lentjes K W Florijn P C Chang W van Dam

A method is described for the semi-automated measurement of inulin concentrations in serum and urine in the presence of glucose. The concentration of glucose is measured simultaneously and is used to correct for almost all "inulin-like" interferences. The inulin standard curve is linear over a wide range (5-2500 mg/l). Between-run precision is < 6% and recovery from spiked sera is 98%. This met...

Journal: :Talanta 2009
Shuyun Zhu Wenxin Niu Haijuan Li Shuang Han Guobao Xu

Single-walled carbon nanohorn (SWCNH) was developed as new adsorbent for solid-phase extraction using 4-nitrophenol as representative. The unique exoteric structures and high surface area of SWCNH allow extracting a large amount of 4-nitrophenol over a short time. Highly sensitive determination of 4-nitrophenol was achieved by linear sweep voltammetry after only 120s extraction. The calibration...

Journal: :Journal of chromatographic science 2013
Renu Chib Bhahwal Ali Shah Samar Singh Andotra Vikram Bharadwaj Rajinder Kumar Gupta Subhash Chandra Taneja Ravi Kant Khajuria

This paper describes the development of a normal-phase liquid chromatography ultraviolet-diode array detection method for the simultaneous quantification of parthenin and coronopilin in the leaves and flowers of Parthenium hysterophorous. The compounds were analyzed on a Merck Si60 silica column (5 µm, 250 × 4 mm) using an isocratic 15:85 mixture of isopropyl alcohol and hexane. The calibration...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2004
Hitoshi Kodamatani Keiitsu Saito Nobumitsu Niina Shigeo Yamazaki Akihiko Muromatsu Ikuo Sakurada

A new sensitive determination method of domoic acid based on the chemiluminescent reaction of tris(2,2'-bipyridine)ruthenium(III) has been developed. The method exhibited good reproducibility. The relative standard deviation of six replicate measurements was 1.6% for 10 ng ml(-1). A calibration graph, based on a standard domoic acid solution, was linear over the range of 1 - 500 ng ml(-1) (coef...

Journal: :The Journal of Automatic Chemistry 1995
Manuel Agudo Angel Ríos Miguel Valcárcel Andrei Danet

An automatic procedure for calibration in continuous-flow systems is proposed. A flow gradient unit in the sample channel, controlled via a switching valve, delivers a concentration gradient of the standard so that the standard concentration varies with time after the flow-rate gradient is started. Thus, the signal (absorbance)- concentration relationship can be determined and checked for (reca...

Journal: :Analytical and bioanalytical chemistry 2006
Laura Gámiz-Gracia Luis Cuadros-Rodríguez Jorge J Soto-Chinchilla José F Huertas-Pérez Antonio González-Casado Ana M García-Campaña

A new strategy is proposed for verifying if recovery factor is constant and independent of the real analyte content of samples. A signal-recovery function has been developed on the basis of measurement of spiked test samples before and after a pre-treatment step and considering, as starting point, a recent IUPAC recommendation which distinguishes between two terms--recovery factor, R, and appar...

Journal: :Clinical chemistry 2008
Steve Shiraishi Paul W N Lee Andrew Leung Victor H H Goh Ronald S Swerdloff Christina Wang

BACKGROUND Recent reports have described inherent problems with androgen immunoassays compared with mass spectrometry analyses. METHODS We developed a method for measuring serum testosterone (T) and 5alpha-dihydrotestosterone (DHT) simultaneously via liquid-liquid extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) with positive-mode electrospray ionization. RES...