نتایج جستجو برای: thermal and fast equivalent dose
تعداد نتایج: 16944698 فیلتر نتایج به سال:
Background: The aim of this study was to develop and implement a Monte Carlo framework for evaluation of patient specific out-of-field organ equivalent dose (OED). Materials and Methods: Dose calculations were performed using a Monte Carlo-based model of Oncor linac and tomographic phantoms. Monte Carlo simulations were performed using EGSnrc user codes. Dose measurements were performed using r...
abstract background: the radiological impact of the use of phosphate fertilizers in soil is due to the internal irradiation of the lung by the alpha particles, short lived radon-thoron progeny and the external irradiation of the body by gamma rays emitted from radionuclides in situ. this paper describes the results of gamma spectrometric measurements of the concentration of the natural radionuc...
in this paper, intelligent water drop algorithm (iwd) is used to analyze single overhead line connected to grid-grounded arrester. in this approach, at first norton’s equivalent circuit of the overhead line over lossy soil is computed by method of moments (mom) and then for the problem under consideration, a nonlinear equivalent circuit in the frequency domain is proposed. finally applying inte...
The investigation of boron biodistribution by neutron induced autoradiography was performed using a CR-39 etched track detector. Calibration samples, made of boronated chicken liver, and freeze-dried mouse tissue samples were irradiated both with thermal and cold neutrons. Digital images were made on the basis of track densities, with the selection of tracks due to 10B(n, alpha)7Li reaction. A ...
background: exposure conditions in ct examinations are quite different from conventional xray. in ct examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. in order to calculate organ effective dose in chest ct, monte carlo simulation has been used in this study. materials and methods: the impact survey data were used to determine the parameter...
Background: Exposure conditions in CT examinations are quite different from conventional Xray. In CT examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. In order to calculate organ effective dose in chest CT, Monte Carlo simulation has been used in this study. Materials and Methods: The Impact survey data were used to determine the ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید