نتایج جستجو برای: thermoluminescence dosimeter
تعداد نتایج: 3015 فیلتر نتایج به سال:
Previous research has proven that the Poly (2,6-dimethyl-1, 4-phenylene oxide) (PPO) dosimeter is capable of receiving both in-air and underwater UV exposures that are significantly greater than those of the more commonly used polysulphone dosimeter, within a range of accuracy close to what would be expected of dosimetric measurements made in-air provided that the necessary calibrations are com...
Accurate dose measurement tools are needed to evaluate the radiation dose delivered to patients by using modern and sophisticated radiation therapy techniques. However, the adequate tools which enable us to directly measure the dose distributions in three-dimensional (3D) space are not commonly available. One such 3D dose measurement device is the polymer-based dosimeter, which changes the mate...
The response of high-dose-range chemical dosimeters is dependent on the dosimeter temperature during irradiation. Typically, irradiation temperatures are estimated by measurements, calculations, or some combination of the two. Then using the temperature coefficient for the dosimetry system, the dosimeter response is adjusted or corrected to be consistent with the irradiation temperature for the...
This study was conducted as part of a project involving the evaluation of a new type of noise exposure monitoring paradigm. Laboratory tests were conducted to assess how "nonstandard" dosimeter microphones and microphone positions measured noise levels under different acoustical conditions (i.e., diffuse field and direct field). The data presented in this article reflect measurement differences...
میزان موفقیت در پرتودرمانی به درستی و دقت میزان دز جذب شده در تومور بستگی دارد و معمولا به علت غیر عملی بودن اندازه گیری مستقیم دز جذب شده در بیماران از فانتوم استفاده می شود. در این تحقیق مقایسه دز تجویزی و دز جذبی در میدان های درمانی تنه در بیماری های هوچکین و آدنوکارسینومای رحم انجام پذیرفته است. روش درمانی را در این دو بیماری روی فانتوم اعمال کرده و دز جذبی در مرکز و نقاط مجاور تومورها با ا...
Background: Interventional cardiology procedures such as coronary angiography (CA) and percutaneous transluminal coronary angiography (PTCA) has been increased recent years. The purpose of this study was to measurement of effective dose to cardiology staffs who operate near the patient and are exposed to non-uniform radiation field due to patient scattered radiation. Materials and Methods: This...