نتایج جستجو برای: thermoluminescent dosimetry

تعداد نتایج: 8409  

Journal: :Radiation protection dosimetry 2016
I Clairand M Ginjaume F Vanhavere E Carinou J Daures M Denoziere E H Silva M Roig S Principi L Van Rycheghem

In the context of the decrease in the eye lens dose limit for occupational exposure to 20 mSv per year stated by the recent revision of the European Basic Safety Standards Directive 2013/59/EURATOM, the European Radiation Dosimetry Group (EURADOS) has organised in 2014, for the first time, an intercomparison exercise for eye lens dosemeters. The main objective was to assess the capabilities of ...

Journal: :Medical physics 2002
M Bucciolini S Russo F Banci Buonamici S Pini P Silli

A 6 MV photon beam from Linac SL75-5 has been collimated with a new micromultileaf device that is able to shape the field in the two orthogonal directions with four banks of leaves. This is the first clinical installation of the collimator and in this paper the dosimetric characterization of the system is reported. The dosimetric parameters required by the treatment planning system used for the...

2015
Marcos Ely Almeida Andrade Sergio Flores Campos

The aim of this study was to evaluate the kerma at the surface of the lens in TMJ CBCT and to derive the equivalent dose. An anthropomorphic phantom of the head and neck manufactured by Radiation Support Devices (model RS230) was used. The dosimetric measurements were obtained by using fourteen thermoluminescent dosimetry (TLD) dosimeters (LiF: Mg, Ti), divided in two pairs (one pair for each e...

Journal: :International journal of radiation oncology, biology, physics 1999
S J Goetsch B D Murphy R Schmidt J Micka L De Werd Y Chen S Shockley

PURPOSE The purpose of this study was to evaluate the characteristics of a new rotating gamma system for stereotactic radiosurgery by comparison with a well accepted system. METHODS AND MATERIALS A novel gamma unit for stereotactic radiosurgery has been developed and distributed to 15 hospitals in China. The unit contains 30 cobalt-60 gamma radiation sources with initial activity of 200 Ci (7...

2012
Mohammad Taghi Bahreyni Toossi Malakeh Malekzadeh

BACKGROUND With the increase of X-ray use for medical diagnostic purposes, knowing the given doses is necessary in patients for comparison with reference levels. The concept of reference doses or diagnostic reference levels (DRLs) has been developed as a practical aid in the optimization of patient protection in diagnostic radiology. OBJECTIVES To assess the radiation doses to neonates from d...

2008
Turan Olgar Esra Onal Dogan Bor Nurullah Okumus Yildiz Atalay Canan Turkyilmaz Ebru Ergenekon Esin Koc

OBJECTIVE The aim of this work was to determine the radiation dose received by infants from radiographic exposure and the contribution from scatter radiation due to radiographic exposure of other infants in the same room. MATERIALS AND METHODS We retrospectively evaluated the entrance skin doses (ESDs) and effective doses of 23 infants with a gestational age as low as 28 weeks. ESDs were dete...

2005
A. I. Stochioiu M. C. Sahagia I. I. Georgescu F. Scarlat

The crystalline substances are the most used for Thermoluminescent Dosimetry (TLD) purposes. The crystalline structure allows for a controlled impurification with activators in order to improve their dosimetric parameters. The activators introduced into the crystalline network [1], enhance the number of electrons and hole traps inside the forbidden band. In the first step, immediately after the...

2009
SY Lam SI Bux G Kumar KH Ng AF Hussain

PURPOSE To compare the image quality of the low-dose to the standard-dose protocol of MDCT scanning of the paranasal sinuses, based on subjective assessment and determine the radiation doses to the eyes and thyroid gland and dose reduction between these two protocols. MATERIALS AND METHODS 31 adult patients were scanned. Prior to scanning, thermoluminescent dosimeters (TLDs) were placed at 4 ...

2013
Jessie Y. Huang David S. Followill Xin A. Wang Stephen F. Kry

Although treatment planning systems are generally thought to have poor accuracy for out-of-field dose calculations, little work has been done to quantify this dose calculation inaccuracy for modern treatment techniques, such as intensity-modulated radiation therapy (IMRT), or to understand the sources of this inaccuracy. The aim of this work is to evaluate the accuracy of out-of-field dose calc...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید