نتایج جستجو برای: transient stability improvement

تعداد نتایج: 721263  

2016
Kamal Tripathi

For improvement of transient response of the error signal all the closed loop control system requires the controller. The simplicity, robustness and ease of implementation has attracted the use of Proportional, Integral and Derivative (PID) controllers. Though the tuning of PID controllers in real time is quite difficult and moreover it lacks the disturbance rejection capability. Internal model...

2017
R. Lyu Y. Xue F. Xue Q. Wu G. Yang H. Zhou P. Ju

In almost all the literatures, the qualitative assessment of transient angle stability extracts the angle information of generators based on the swing curve. As the angle (or angle difference) of concern and the threshold value rely strongly on the engineering experience, the validity and robust of these criterions are weak. Based on the stability mechanism from the extended equal area criterio...

2000
Damien Ernst

The question of transient stability control is revisited, various types of controls are identified, and a general approach to closed-loop emergency control is proposed. The focus is on feasibility aspects, general salient features and illustration of stabilization capabilities of an emergency control scheme relying on generation shedding.

2004
S. Krishna K. R. Padiyar

Ab3tractOnline transient stability assessment (TSA) of a power system is not yet feasible due to the intensive computation involved. Artificial neural networks(ANN) have been proposed as one of the approaches to this problem because of its ability to quickly map nonlinear relationships between the input data and the output. In this paper a review of the previously. published papers on TSA using...

Journal: :Electronics 2023

Virtual synchronous generator (VSG) control is based on the fact that line impedance in a microgrid highly inductive. This assumption was made due to emulation of stator winding an electrical machine. concept can affect controllability with complex impedance, generating deviations chosen operation point. To overcome this issue, additional techniques must be implemented. paper describes novel ma...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی اصفهان - دانشکده شیمی 1389

in this thesis, a new optically active poly(amide-imide) (pai) was synthesized by the indirect polycondensation reaction of the l-phenylalanine based diacid chloride and 4,4?-diaminodiphenylether in the presence of triethylamine in n-methyl-2-pyrrolidone. the formation of pai was confirmed by ftir, 1h nmr and elemental analysis. in next step, the surface of titanium dioxide (tio2) nanoparticles...

2009
Rene Avila Jay Giri

Transient Stability Assessment, preventive control measures and dynamic A X calculations are addressed for the new deregulated EMS system. The combination of time domain analysis, SIME and Optimal Power Flow provide a reliable solution for future transaction requirements and the current operating point.

2015
Hassan L. Hijazi Terrence W. K. Mak Pascal Van Hentenryck

We address the problem of power system restoration after a significant blackout. Prior work focus on optimization methods for finding high-quality restoration plans. Optimal solutions consist in a sequence of grid repairs and corresponding steady states. However, such approaches lack formal guarantees on the transient stability of restoration actions, a key property to avoid additional grid dam...

2001
Damien Ernst Daniel Ruiz-Vega Mania Pavella

A unified approach to transient stability closed-loop control is presented. It relies on the general transient stability method called SIME, from which the Preventive and the Emergency SIMEs are derived. The Preventive SIME uses time-domain simulations of plausible contingencies prior to their occurrence, for the online power system monitoring from the control room. The Emergency SIME, on the o...

Journal: :Technology and Economics of Smart Grids and Sustainable Energy 2019

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید