نتایج جستجو برای: absorbed dose measurement
تعداد نتایج: 748807 فیلتر نتایج به سال:
Introduction: The determination of patient’s absorbed dose is the first step of radiation protection which depends on the quantification of organ activity in nuclear medicine. The aim of the present study was to determine the absorbed dose by patient’s uterus following myocardial perfusion scan with 99mTC-sestamibi using Theroluminescnce dosimetry (TLD) and conjugate-view metho...
MARIO CHEN MOK: Logistic Dose-Response Models under Compliance Measurement Error for some Problems in Inhalation Toxicology. (Under the direction ofDr. PRANAB KUMAR SEN.) In a classical measurement error model, true regressors, though unknown, vary stochastically around' the specified dose level. In inhalation toxicology problems, however, it is reasonable to assumed that the administered dose ...
The water equivalency of five "water-equivalent" solid phantom materials was evaluated in terms of output calibration and energy characterization over a range of energies for both photon (Co-60 to 24 MV) and electron (6-20 MeV) beams. Evaluations compared absorbed doses calculated from ionization measurements using the same dosimeter in the solid phantom materials and in natural water (H2O). Io...
NIST developed the alanine dosimetry system in the early 1990s to replace radiochromic dye film dosimeters. Later in the decade the alanine system was firmly established as a transfer service for high-dose radiation dosimetry and an integral part of the internal calibration scheme supporting these services. Over the course of the last decade, routine monitoring of the system revealed a small bu...
Introduction Radon is a colorless and tasteless gas which exists in most soils. It is a substance that poses a potential risk for lung cancer in case a person is exposed to high levels over long periods of time. The Environmental Protection Agency (EPA) estimates that 90% of lung cancers per year are caused by radon. The aim of this paper is to estimate the absorbed doses of 222Rn by MCNPX simu...
computed tomographyrepresents about 10% of all diagnostic radiology procedures, but it isresponsible for almost 50% - 60% of exposure from diagnostic procedures. inhead ct, other critical organs such as eye lenses and thyroids are in theradiation field. therefore, dose assessment in these organs is very important.the aim of this study is to estimate the absorbed dose in critical organs ofpatien...
background: two protocols of aapm tg-51 and iaea trs-398 were compared followed by a measurement and monte carlo simulation of beam quality correction factor, kq, aapm tg-51 and iaea trs-398 protocols were compared for the absorbed dose to water for dw, and kq parameters. materials and methods: dose measurements by either protocols were performed with cylindrical and plane parallel chambers for...
Introduction: There are many ways to treat cancer and pain relief. One of the methods is radiopharmaceutical therapy. Indium 111-rituximab contains the radioisotope indium-111 and rituximab. The Indium-111, after decay, emits gamma rays with energies of 245 KeV and 171 KeV, and beta-radiation of 26 KeV. In this study, the absorbed dose of 111In-Rituximab in human body was calcu...
A car-borne survey was carried out in the northwestern, or Tokatsu, area of Chiba Prefecture, Japan, to make a detailed distribution map of absorbed dose rate in air four years after the Fukushima Daiichi Nuclear Power Plant accident. This area was chosen because it was the most heavily radionuclide contaminated part of Chiba Prefecture and it neighbors metropolitan Tokyo. Measurements were per...
In this paper, an experimental setup is used to measure the temperature dependence of the refractive index of a water phantom. In radiation calorimetry by laser beams and interferometric systems, the amount of change induced by radiation within the phantom can be accurately measured. Absorption of dose and the resulted change in temperature changes the refractive index within the material. In o...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید