نتایج جستجو برای: attenuation emission data

تعداد نتایج: 2593617  

Journal: :Physical review letters 2002
R Vlutters O M J van't Erve S D Kim R Jansen J C Lodder

The relative importance of interface, volume, and thermal scattering in spin-dependent hot-electron transmission of magnetic trilayers is quantified. While interfaces produce significant attenuation (factor 2.2 per interface), the spin asymmetry is dominated by volume scattering. Extracted thermal attenuation lengths (130 A at 300 K for Ni80Fe20) show that thermal spin-wave scattering is strong...

Journal: :Environmental Health Perspectives 1975

Journal: :NeuroImage 2017
Abolfazl Mehranian Habib Zaidi Andrew J. Reader

With the advent of time-of-flight (TOF) PET scanners, joint maximum-likelihood reconstruction of activity and attenuation (MLAA) maps has recently regained attention for the estimation of PET attenuation maps from emission data. However, the estimated attenuation and activity maps are scaled by unknown scaling factors. We recently demonstrated that in hybrid PET-MR, the scaling issue of this al...

2001
Leonid A Kunyansky L A Kunyansky

We present a new reconstruction algorithm for single-photon emission computed tomography. The algorithm is based on the Novikov explicit inversion formula for the attenuated Radon transform with non-uniform attenuation. Our reconstruction technique can be viewed as a generalization of both the filtered backprojection algorithm and the Tretiak–Metz algorithm. We test the performance of the prese...

Journal: :Journal of nuclear medicine technology 2006
Daniel von Borczyskowski Ulrike Schulte Winfried Brenner Malte Clausen Ralph Buchert

In infants, brain (18)F-FDG PET often requires sedation. To keep the sedation mild, the PET acquisition time should be kept short. Therefore, calculated attenuation correction is often preferred to measured attenuation correction. In addition, the infant should be positioned as comfortably as possible. Here, we report a case in which the infant's fist was near her head, resulting in severe arti...

2008
H. F. Wehrl A. Kolb M. S. Judenhofer M. P. Lichy C. D. Claussen B. J. Pichler

Hybrid imaging devices combining Positron-Emission-Tomography (PET) with Magnetic-Resonance-Imaging (MRI) have been shown to possess a great potential for small animal studies. Recently PET/MR systems have also been built for human applications. Here we present an evaluation of the first hybrid PET/MR device, which has the capabilities to perform simultaneous PET/MR acquisitions of the human br...

2015
Yueh Hsu Cheng-Ying Chou

National Taiwan University, Taipei, Taiwan A quantitative reconstruction of radiotracer activity distribution in positron emission tomography (PET) requires correction of attenuation, which was typically estimated through transmission measurements. The advancement in hardware development has prompted the use of time-of-flight (TOF) to improve PET imaging. Recently, the application of TOF-PET ha...

Journal: :CoRR 2007
Tadej Kosel Igor Grabec

The intelligent acoustic emission locator is described in Part I, while Part II discusses blind source separation, time delay estimation and location of two simultaneously active continuous acoustic emission sources. The location of acoustic emission on complicated aircraft frame structures is a difficult problem of non-destructive testing. This article describes an intelligent acoustic emissio...

2017
Martin L. Lassen Otto Muzik Thomas Beyer Marcus Hacker Claes Nøhr Ladefoged Jacobo Cal-González Wolfgang Wadsak Ivo Rausch Oliver Langer Martin Bauer

The purpose of this study was to test the feasibility of migrating a quantitative brain imaging protocol from a positron emission tomography (PET)-only system to an integrated PET/MR system. Potential differences in both absolute radiotracer concentration as well as in the derived kinetic parameters as a function of PET system choice have been investigated. Five healthy volunteers underwent dyn...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید