2007
Tadahiro Kurosawa Yuuichirou Morishita Tsuyoshi Matsumoto Norio Saito

The parallel-plate free-air ionization chambers are used for X-rays air-kerma rate standards at National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST). The diaphragms are used to free-air chambers to fix the air volume of ionizing region in chambers. It means that absolute air-kerma rates are defined for collimated x-ray beams, beca...

2001
Q. Z. YIN S. B. JACOBSEN C.-T. LEE W. F. MCDONOUGH R. L. RUDNICK

The Re-Os isotopic system is currently limited as a chronometer because of the lack of accurate gravimetric standards for Os spike calibration and uncertainty of the Re half-life, which is also dependent on the accuracy of Os spike calibration. We demonstrate that the concentration of an Os spike can be calibrated accurately to 60.2%. The accuracy of this calibration was achieved by using a hig...

Journal: :Clinica chimica acta; international journal of clinical chemistry 2006
Judith A P Bons Douwe de Boer Marja P van Dieijen-Visser Will K W H Wodzig

BACKGROUND Protein profiling by surface enhanced laser desorption ionization-time of flight-mass spectrometry (SELDI-TOF-MS) is gaining importance as a diagnostic tool for a whole range of diseases. This report describes a QC procedure, which acts prospectively by checking the calibration before starting profiling experiments. METHODS A well-defined protocol for calibration of the Protein Bio...

2009
J. Brožovský D. Procházka D. Beneš

Currently, in civil engineering, high performance concrete i.e. concretes whose minimum compression strength is equal or more than 65 MPa are increasingly used. Side effect of it is need for determination of their construction strength. In particular, recently built high performance structures suffer from sampling of drill cores. Therefore, noninvasive impact hammers – to be specific Schmitt im...

Journal: :Radiation protection dosimetry 2016
A Malusek M Sandborg G Alm Carlsson

Modern X-ray units register the air kerma-area product, PKA, with a built-in KAP meter. Some KAP meters show an energy-dependent bias comparable with the maximum uncertainty articulated by the IEC (25 %), adversely affecting dose-optimisation processes. To correct for the bias, a reference KAP meter calibrated at a standards laboratory and two calibration methods described here can be used to a...

2017
D. G. Eitzen H. Berger George Birnbaum

The National Bureau of Standards (NBS) is beginning to provide a mechanism for traceability for a number of NDE measurement procedures, an activity that is expected to have a significant, positive impact on the reproducibility and accuracy of NDE measurements. Much of the NDE standards activity has been in ultrasonics and acoustic emission, this effort leading to calibration services for ultras...

2003
Randolph E. Elmquist Dean G. Jarrett George R. Jones Marlin E. Kraft Scott H. Shields Ronald F. Dziuba

At the National Institute of Standards and Technology (NIST), the U.S. representation of the ohm is based on the quantum Hall effect, and it is maintained and disseminated at various resistance levels by working reference groups of standards. This document describes the measurement systems and procedures used to calibrate standard resistors and current shunts of nominal decade values in the res...

2007
Marko Jurčević

− A growing number of measurements in commercial and industrial sector need to refer to the traceability to the national (and international) standards. Instrument and reference standards calibration is resource and time consuming. Since many of the available digital instruments provide some communication interfaces and the internet-enabled metrology is rapidly developing in the recent years, it...

Journal: :Zeitschrift fur klinische Chemie und klinische Biochemie 1972
R Watkins L M Weiner B Zak

' Several perplexing questions involving standardization techniques surface when ultraviolet spectrophotometry is used for the determination of unknown ribonucleic acids isolated from tissue sources. One must consider the effect of hydrolysis on total absorbance, nucleotide makeup of a ribonucleic acid versus molar absorptivity and additivity of riucleotides on total measured absorbance. Experi...

Journal: :Journal of lipid research 2014
Martin Gantner Günter Schwarzmann Konrad Sandhoff Thomas Kolter

Within recent years, ganglioside patterns have been increasingly analyzed by MS. However, internal standards for calibration are only available for gangliosides GM1, GM2, and GM3. For this reason, we prepared homologous internal standards bearing nonnatural fatty acids of the major mammalian brain gangliosides GM1, GD1a, GD1b, GT1b, and GQ1b, and of the tumor-associated gangliosides GM2 and GD2...