نتایج جستجو برای: diameter measurement

تعداد نتایج: 544247  

Journal: :iranian journal of nuclear medicine 2016
sousan shafiei vahid-reza dabbagh hamideh sadra ramin sadeghi seyed mohsen seyedi

introduction: renal length measurement is an important diagnostic clue in several urinary tract abnormalities. although ultra sonography is the most frequent used modality for renal size estimation, renal diameter assessment by 99mtc-dmsa scintigraphy is of great value. by now, pointing to the renal size in the 99mtc-dmsa scintigraphy report has not been recommended by guidelines. if the validi...

Journal: :AJNR. American journal of neuroradiology 2006
E S Bartlett S P Symons A J Fox

PURPOSE Carotid stenosis quantification traditionally uses measurements of narrowest stenosis diameter. The stenotic carotid lumen, however, is often irregularly shaped. New PACS workstation tools allow for more precise calculation of carotid geometry. We compare the narrowest stenosis diameter with 2D area stenosis measurements, with the hypothesis that the narrowest diameter is a good predict...

Journal: :AJR. American journal of roentgenology 2010
Seitaro Oda Kazuo Awai Kohei Murao Akio Ozawa Yumi Yanaga Koichi Kawanaka Yasuyuki Yamashita

OBJECTIVE The purpose of this study was to investigate the accuracy and reproducibility of results acquired with computer-aided volumetry software during MDCT of pulmonary nodules exhibiting ground-glass opacity. MATERIALS AND METHODS To evaluate the accuracy of computer-aided volumetry software, we performed thin-section helical CT of a chest phantom that included simulated 3-, 5-, 8-, 10-, ...

Journal: :Hypertension 2013
Howard H Carter Ellen A Dawson Gurpreet K Birk Angela L Spence Louise H Naylor N Timothy Cable Dick H J Thijssen Daniel J Green

The impact of manipulating shear stress on conduit artery vasodilation has not been comprehensively described in vivo. We hypothesized that manipulation of SR through the brachial and radial arteries would be associated with corresponding changes in diameter. We performed a series of studies involving the following: (1) leg cycle exercise at increasing intensities (≈70 and 85% maximum heart rat...

Introduction: Measurement of central venous pressure can be regarded as a beneficial guide in order to assess a patient's hemodynamic status, specifically in patient with sever sepsis and septic shock, for whom a central venous pressure of less than 8mmhg is considered as an indicator for aggressive intravenous fluid replacement. Therefore, this study aimed to investigate the ultrasonographic e...

E. Fathi, M. Ahmadi-Hamedani R. Farahzadi

To evaluate the prognostic significance of clinicopathological measurement in the diagnosis of acute myocardial infarction (MI) in sheep, acute MI was induced by ligation of left anterior descending coronary artery (LAD). For this purpose, twenty four healthy sheep were divided into the sham-operated or control group (group I, thoracotomy without MI) and the experimental group (group II, with M...

Journal: :emergency journal 0
bahman naghipour department of anesthesiology, tabriz university of medical sciences, tabriz, iran gholamreza faridaalaee emergency department, maragheh university of medical sciences, maragheh, iran

introduction: the correlation of central venous pressure (cvp) with inferior vena cava (ivc) sonographic diameter has been reported in several studies. however, few studies have attempted to find the best anatomic location of measurement. therefore, the purpose of this study was determining the best anatomic location to find precise correlation between cvp and ivc diameter using transesophageal...

Introduction: Quality assurance in Computed tomography (CT) centers in developing countries are largely hindered by the unavailability of CT phantoms. The development of a local CT phantom for the measurement of organ radiation absorbed dose is therefore requisite. Material and Methods: Local CT phantoms were designed to meet the standard criteria of 32 cm diameter for body, 16 cm diameter for...

Journal: :JCP 2015
Wasin Poncheewin Monravee Tumkosit Rajalida Lipikorn

This paper presents a method to automatically measure cardio-thoracic ratio (CTR) from a chest radiographic images using non-linear least square approximation and local minimum. The proposed method consists of initial boundary point identification, cardiac diameter measurement, thoracic diameter measurement and cardio-thoracic ratio measurement. First, the initial boundary points used to approx...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید