نتایج جستجو برای: die entry radius

تعداد نتایج: 243349  

Journal: : 2021

This study investigates the thickness variation behavior of deep drawing conical products under effect different forming parameters such as die wall inclination angle, punch velocity, sheet thickness, and metal type. Two types were used, low carbon (AISI 1008) galvanized steel sheets, 110 mm diameters circular blanks at 0.9 1.2mm formed by tooling set (punch, die, blank holder). The dies angles...

Journal: :anesthesiology and pain medicine 0
ali tabrizi orthopedics surgery department, imam khomeini hospital, urmia university of medical sciences, urmia, iran; orthopedics surgery department, imam khomeini hospital, urmia university of medical sciences, urmia, iran. tel: +98-9143130829 fardin mirza tolouei orthopedics surgery department, imam khomeini hospital, urmia university of medical sciences, urmia, iran ebrahim hassani department of anesthesiology, imam khomeini hospital, urmia university of medical sciences, urmia, iran hassan taleb orthopedics surgery department, imam khomeini hospital, urmia university of medical sciences, urmia, iran asghar elmi orthopedics surgery department, shohada educational hospital, tabriz university of medical sciences, tabriz, iran

conclusions hematoma block analgesia used in distal radius fractures of the elderly is a very safe and effective method that seems preferable to general anesthesia in emergency departments. objectives the aim of this study was to compare two analgesia methods including hematoma block and general anesthesia in people over 60 years in the orthopedic emergency department. methods 68 elderly patien...

2013
Melanie Schnell Undine Erlekam P. R. Bunker Gert von Helden Jens-Uwe Grabow Gerard Meijer Ad van der Avoird

Das Benzoldimer ist ein Prototypsystem f r die Untersuchung nichtkovalenter Wechselwirkungen zwischen aromatischen Systemen, die durch Dispersionskr fte bestimmt werden. Es weist zwei miteinander konkurrierende Gleichgewichtsstrukturen auf: eine gekippte, T-fçrmige (edge-toface) und eine, in der die beiden Benzolringe parallel angeordnet, aber zueinander verschoben sind (stacked). Sowohl der ve...

Journal: :Wirtschaftsinformatik & Management 2009
Thorsten Lenk

Deutschland steht 2009 vor einem überaus schwierigen Jahr. Vorausschauende Manager schielen aber weniger auf die nicht beeinflussbaren Eckdaten, sondern finden heraus, welche Verbesserungspotenziale in ihrer Firma schlummern. Eine Alternative zu Cost-Cutting-Programmen kann die Optimierung des Projektmanagements sein. Ein kritischer Blick auf den Markt der dafür erforderlichen Projektmanagement...

E. Eshghi, M Kadkhodayan,

High speed and absence of a precise control over pressure distribution confine sheet Electromagnetic Forming into a die to simple shapes having shallow depth. It is possible to reach a higher depth by using a convex punch instead of a concave die. In this study, sheet Electromagnetic Forming on a punch and sheet Electromagnetic Forming into a die are investigated. The electromagnetic part of th...

The hydrostatic extrusion is a new method of extrusion process. The most important advantage of this method is reduction of friction and close tolerance for the coating thickness. In this study, the hydrostatic extrusion simulation of bimetallic wires has performed using of finite element method. In the following the advantages of hydrostatic extrusion compared to the direct extrusion are prese...

Journal: :Journal of Chemistry 2022

In order to study the die wear law of rotary fine blanking helical cylindrical gear, a three-dimensional rigid plastic finite element model gear is established on Deform-3D software platform. Based Archard model, this paper analyzes in process, obtains distribution each point working surface die, determines maximum area, and makes comparative analysis with spur gear. Through single factor varia...

2014
Ben Brooker P. Christian Harris Leo T. Donnan H. Kerr Graham

INTRODUCTION Diaphyseal forearm fractures are common in children and adolescents. Intramedullary fixation with flexible nails has a high success rate. Complications related to the insertion of the radial nail include injury to the superficial branch of the radial nerve and rupture of the extensor pollicis longus (EPL) tendon. MATERIALS AND METHODS We report a series of nine patients who susta...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید