2011
Antonella Fogliata Giorgia Nicolini Alessandro Clivio Eugenio Vanetti Luca Cozzi

BACKGROUND A new algorithm for photon dose calculation, Acuros XB, has been recently introduced in the Eclipse, Varian treatment planning system, allowing, similarly to the classic Monte Carlo methods, for accurate modelling of dose deposition in media. Aim of the present study was the assessment of its behaviour in clinical cases. METHODS Datasets from ten breast patients scanned under diffe...

Journal: :Medical physics 2012
M Bueno J Schuemann M Duch H Paganetti

PURPOSE Due to multiple Coulomb scattering in complex geometries, small field dosimetry in proton therapy is challenging. Our goal was to define an indicator for the accuracy of dose delivery based on analytical dose calculations in treatment planning systems for small (e.g. radiosurgery) proton therapy fields. METHODS Seven patients whose treatment involved one or more small fields (below ∼3...

Journal: :iranian journal of cancer prevention 0
hamideh nazemi-gelyan dept. of medical physics, semnan university of medical sciences, semnan, iran hadi hasanzadeh dept. of medical physics, semnan university of medical sciences, semnan, iran yasha makhdumi reza radiotherapy oncology charity center, mashhad, iran sara abdollahi dept. of radiotherapy, iran university of medical sciences, tehran, iran fatemeh akbari reza radiotherapy oncology charity center, mashhad, iran fatemeh varshoee-tabrizi reza radiotherapy oncology charity center, mashhad, iran

background: radiotherapy plays an important role in the management of most malignant and many benign primary central nervous system (cns) tumors. radiotherapy affects both tumor cells and uninvolved normal cells; so, it is important to estimate absorbed dose to organs at risk in this kind of treatment. the aim of this study was to determine the absorbed dose to chiasma, lens, optic nerve, retin...

Bahram Mofid Fahimeh Faghihi Moghadam Mehdi Ghorbani Mohsen Bakhshandeh

Abstract Introduction: The accuracy an assessment of out- of- field dose due to secondary cancer risk is clinically important. Actually radiotherapy treatment planning systems are not commissioned for the out-of-field dose calculations, so the estimation of dose distributions by TPSs beyond the borders of treatment fields is not well calculate...

Journal: :Medical physics 2010
Susan L Richardson Ramiro Pino

PURPOSE To investigate the dosimetric effect of the air inside the SAVI™ partial breast irradiation device. METHODS The authors have investigated how the air inside the SAVI™ partial breast irradiation device changes the delivered dose from the homogeneously calculated dose. Measurements were made with the device filled with air and water to allow comparison to a homogenous dose calculation d...

Journal: :Journal of the Atomic Energy Society of Japan / Atomic Energy Society of Japan 1994