نتایج جستجو برای: dose distribution verification

تعداد نتایج: 975918  

Journal: :Journal of cancer research and therapeutics 2007
Anup K Bhardwaj T S Kehwar S K Chakarvarti A S Oinam S C Sharma

The aim of this paper is to analyze the positional accuracy, kinetic properties of the dynamic multileaf collimator (MLC) and dosimetric evaluation of fractional dose delivery for the intensity modulated radiotherapy (IMRT) for step and shoot and sliding window (dynamic) techniques of Varian multileaf collimator millennium 80. Various quality assurance tests such as accuracy in leaf positioning...

2014
Mara Severgnini Mario de Denaro Marina Bortul Cristiana Vidali Aulo Beorchia

Intraoperative electron radiation therapy (IOERT) cannot usually benefit, as conventional external radiotherapy, from software systems of treatment planning based on computed tomography and from common dose verify procedures. For this reason, in vivo film dosimetry (IVFD) proves to be an effective methodology to evaluate the actual radiation dose delivered to the target. A practical method for ...

Journal: :Frontiers in Medicine 2023

Recently, in-beam positron emission tomography (PET) has been actively researched for reducing biological washout effects and dose monitoring during irradiation. However, the distribution does not precisely reflect since production ionization are completely different physical processes. Thus, a novel system was proposed to determine proton range by measuring scattered protons with dozens of sci...

2014
Chris Beltran Yingcui Jia Roelf Slopsema Daniel Yeung Zuofeng Li

The purpose of this study was to develop a simplified methodology that will produce Monte Carlo (MC) dose distribution for proton therapy which can be used as a clinical aid in determining the adequacy of proton plans produced from the treatment planning system (TPS). The Geant4 Monte Carlo toolkit was used for all simulations. The geometry of the double scatter nozzle in the simulation was a s...

2017
Shih-Ming Hsu Chao-Hsiung Hung Yi-Jen Liao Hsiao-Mei Fu Jo-Ting Tsai Yung-Hui Huang David Y. C. Huang

CyberKnife is one of multiple modalities for stereotactic radiosurgery (SRS). Due to the nature of CyberKnife and the characteristics of SRS, dose evaluation of the CyberKnife procedure is critical. A radiophotoluminescent glass dosimeter was used to verify the dose accuracy for the CyberKnife procedure and validate a viable dose verification system for CyberKnife treatment. A radiophotolumines...

2017
Astrid van der Horst Antonetta C. Houweling Geertjan van Tienhoven Jorrit Visser Arjan Bel

Pancreatic tumors show large interfractional position variation. In addition, changes in gastrointestinal gas volumes and body contour take place over the course of radiation therapy. We aimed to quantify the effect of these anatomical changes on target dose coverage, for the clinically used fiducial marker-based patient position verification and, for comparison, also for simulated bony anatomy...

K. Adinehvand, M.H. Zahmatkesh, M.R Aghamiri, S. Bagheri, Sh. Akhlaghpour,

Background: The purpose of this study was to evaluate the dependency of MAGICA polymer gel dosimeter response (R2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. Materials and Methods: The sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modalit...

Journal: :iranian journal of radiation research 0
a.a. mowlavi physics department, school of sciences, sabzevar tarbiat moallem university, sabzevar, iran f. cupardo servizio di fisica sanitaria, ospedali riuniti di trieste, trieste, italy m. severgnini servizio di fisica sanitaria, ospedali riuniti di trieste, trieste, italy

background: monte carlo and experimental relative dose determination in a water phantom, due to a high dose rate (hdr) 192ir source is presented for real energy spectrum and monochromatic at 356 kev. materials and methods: the dose distribution has been calculated around the 192ir located in the center of 30 cm ×30 cm ×30 cm water phantom using mcnp4c code by monte carlo method. relative dose v...

Journal: :iranian journal of radiation research 0
m.n. anjum a. qadir m. afzal

background: the dosimetric performance of eclipse 6.5 three dimensional treatment planning system (3dtps) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of american association for physicists in medicine task group 53. materials and methods: the calculations were performed by the 3dtps for symmetric as well as asymmetric fields for standar...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید