نتایج جستجو برای: dosimeter

تعداد نتایج: 2113  

2008
N. J. Downs A. V. Parisi

A method for the three dimensional representation of erythemally effective ultraviolet radiation (UVery) incident to the human body has been developed from a series of polysulphone dosimeter (PS) measurements to the face, neck, arms, legs and hands of a manikin model. The technique has been used to represent a series of human UVery exposure patterns in the solar zenith angle (SZA) range 30-50 m...

2003
G.A.P. Cirrone G. Cuttone

Diamond is potentially a suitable material for use as radiation dosimeter; the wide band gap results in low dark currents and low sensitivity to visible light, the high carrier mobility can give rapid response, the very high density of strong bonds in the crystal structure make diamond very resistant to radiation damage; moreover it is tissue equivalent. The more recent advances in the synthesi...

Journal: :Journal of physics. Conference series 2011
J R Newton A Thomas A Appleby C Marsden E A Christman J G Wolodzko M Oldham

A preliminary investigation into the efficacy of a new 3D dosimetry material, RadGel™, for verification of radiation therapy dose distributions is presented. Small volumes of RadGel™ were found to exhibit a linear, reproducible response to dose. A gradual increase in optical-density (OD) with time was observed, suggesting scanning should be completed within 18 hours to keep a linear correlation...

2011
K. Adinehvand B. Azadbakht

The purpose of this study was to evaluate dependence of MAGICA polymer gel dosimeter 1/T2 on different electron energies as well as on different mean dose rates for a standard clinically used Linear accelerator. A calibration curve (in the linear region) based on 12 dosimeters (11 irradiated and one background) was obtained for 6MeV electron beam. Dose rate of dependence was studied in 10MeV el...

2014
T Juang J Adamovics M Oldham

This study investigates a reusable PRESAGE® 3D dosimeter (Presage-RU), which would improve cost-effectiveness and facilitate wider implementation of comprehensive, high resolution 3D dosimetry. Small (1x1x4.5 cm) and large (8 cm diameter, 4.5 cm length) sample dosimeters were irradiated multiple times to characterize dose response (i.e. radiation-induced change in optical density (∆OD)), optica...

Journal: :iranian journal of radiation research 0
f. pake department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran a. takavar department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran h.a. nedaie department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran h.r. saligheh rad department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran e. eqlimi department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran v. vaezzadeh department of radiotherapy oncology, cancer research centre, cancer institute, tehran university of medical sciences, tehran, iran

background:  in this study a series of basic dosimetric properties of a low-density (ld) gel dosimeter are investigated. the dose response is studied regarding to linearity, sensitivity, dose-rate and energy dependence as well as lung tissue equivalence. materials and methods: the ld gel was made by mixing the polymer gel with expanded polystyrene spheres. energy dependence was studied at two d...

Journal: :Nuclear medicine review. Central & Eastern Europe 2013
Kamil Szewczak Sławomir Jednoróg Paweł Krajewski

Presented paper describes the results of the individual doses measurements for ionizing radiation, carried out by the Laboratory of Individual and Environmental Doses Monitoring (PDIS) of the Central Laboratory for Radiological Protection in Warsaw (CLOR) for the medical staff employees in several nuclear medicine (NM) departments across Poland. In total there are48 NM departments in operation ...

2015
Simon Doran Tina Gorjiara Andrzej Kacperek John Adamovics Zdenka Kuncic Clive Baldock

Dosimetry of proton beams using 3D imaging of chemical dosimeters is complicated by a variation with proton linear energy transfer (LET) of the dose-response (the so-called 'quenching effect'). Simple theoretical arguments lead to the conclusion that the total absorbed dose from multiple irradiations with different LETs cannot be uniquely determined from post-irradiation imaging measurements on...

Journal: :Medical physics 2006
Pengyi Guo John Adamovics Mark Oldham

There is a pressing need for a practical three-dimensional (3D) dosimetry system, convenient for clinical use, and with the accuracy and resolution to enable comprehensive verification of the complex dose distributions typical of modern radiation therapy. Here we introduce a dosimetry system that can achieve this challenge, consisting of a radiochromic dosimeter (PRESAGE) and a commercial optic...

Journal: :Medical physics 2009
Claus E Andersen Søren Kynde Nielsen Jacob Christian Lindegaard Kari Tanderup

PURPOSE The purpose of this study is to present and evaluate a dose-verification protocol for pulsed dose-rate (PDR) brachytherapy based on in vivo time-resolved (1 s time resolution) fiber-coupled luminescence dosimetry. METHODS Five cervix cancer patients undergoing PDR brachytherapy (Varian GammaMed Plus with 192Ir) were monitored. The treatments comprised from 10 to 50 pulses (1 pulse/h) ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید