نتایج جستجو برای: external fixator

تعداد نتایج: 190631  

2010
Karen M. Knapp Ann V. Rowlands Joanne R. Welsman Kenneth M. MacLeod

Disuse osteopenia is a complication of immobilisation, with reversal generally noted upon remobilisation. This case report focuses on a patient who was seen 18 years following a road traffic collision when multiple fractures were sustained. The patient had an external fixator fitted for a tibia and fibula fracture, which remained in situ for a period of 4 years. Following removal, the patient w...

Journal: :The West Indian medical journal 2007
R E C Rose D E P Wright

Congenital pseudarthrosis of the tibia continues to pose one of the most difficult problems in paediatric orthopaedic surgery. The surgical procedures most used for treating congenital pseudarthrosis of the tibia are intramedullary nailing associated with bone grafting, vascularized fibular graft and the Ilizarov external circular fixator. Even when union is achieved, the residual deformities i...

2016
Alfred Cyril Roy Sandeep Albert Mohamad Gouse Dan Barnabas Inja

Several methods for obtaining knee arthrodesis have been described in the literature and world; over, the commonest cause for arthrodesis is a failed arthroplasty. Less commonly, as in this series, post-infective or traumatic causes may also require a knee fusion wherein arthroplasty may not be indicated. We present salient advantages along with the radiological and functional outcome of twenty...

Journal: :Journal of pediatric orthopedics. Part B 2005
John E Handelsman Jacob Weinberg Samara Friedman

Torsional problems of the femur have been traditionally treated by a proximal osteotomy with internal fixation. We elected to perform femoral derotational osteotomies distally. Between September 1994 and April 2001, supracondylar osteotomies were performed on 38 femora in 21 children with torsional and angular deformities. The average age was 9 years (range 5-15 years). Twenty-three femora had ...

Journal: :The Journal of bone and joint surgery. British volume 2002
I C Vossinakis L S Badras

In a prospective, randomised study we have compared the pertrochanteric external fixator (PF) with the sliding hip screw (SHS) in 100 consecutive patients who were allocated randomly to the two methods of treatment. Details of the patients and the patterns of fracture were similar in both groups. Follow-up was for six months. Use of the PF was associated with significantly less blood loss, a sh...

2012
Gregory R Staeheli Michael R Fraser Steven J Morgan

BACKGROUND Placement of external fixation frames is an expedient and minimally invasive method of achieving bone and joint stability in the setting of severe trauma. Although anatomic safe zones are established for placement of external fixation pins, neurovascular structures may be at risk in the setting of severe trauma. CASE REPORT We present a case of a 21-year-old female involved in a hi...

2009
Yngvar Krukhaug Stein Ugland Stein A Lie Leiv M Hove

BACKGROUND AND PURPOSE External fixators allowing movement during fracture healing are commonly used for treatment of unstable distal radius fractures. The dynamic Dynawrist fixator with the distal pins in metacarpal bone may avoid fixation problems in comminuted fractures and may reduce the risk of nerve injury. We compared anatomical and functional outcome for the well-established Hoffmann co...

2016
N. Ferreira L. C. Marais

Femoral non-unions are difficult to treat even for the experienced orthopaedic trauma surgeon. If the non-union follows failure of modern stable internal fixation, the complexity of the management is further increased. We report two cases of stiff hypertrophic femoral non-unions after failed locking plate fixation that were successfully treated with a new hexapod circular external fixator. In a...

Journal: :Revista brasileira de ortopedia 2015
Noel Oizerovici Foni Felipe Augusto Ribeiro Batista Luís Henrique Camargo Rossato José Octavio Soares Hungria Marcelo Tomanik Mercadante Ralph Walter Christian

OBJECTIVE To conduct a retrospective analysis on cases undergoing inspection of orthopedic damage, at an orthopedic emergency service in a teaching hospital, with the aim of evaluating patients with postoperative infection after conversion to internal osteosynthesis. METHODS This was a retrospective analysis covering the period from June 2012 to June 2013, on patients who underwent inspection...

Journal: :Acta orthopaedica Belgica 2007
Ayman M Ali Mostafa Abdelkhalek Abdelrahman El-Ganiney

Intertrochanteric fractures of the femur were treated with an external fixator in 38 elderly high-risk patients between November 2005 and February 2007. The mean operation time was 25 min (range: 20 to 32 min), the mean fluoroscopy time was 15 sec (range: 10 to 18 sec), and the mean hospital stay was four days (range: 3 to 7 days). The average time to union was 9.5 weeks. No deep pin track infe...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید