نتایج جستجو برای: flow pump
تعداد نتایج: 537446 فیلتر نتایج به سال:
BACKGROUND Centrifugal pumps are used increasingly for temporary mechanical support for the treatment of cardiogenic shock. However, centrifugal pumps can generate excessive negative pressure and are afterload sensitive. A previously developed modified roller pump mitigates these limitations both in vitro and in preliminary animal experiments. We report the results of intermediate-term testing ...
The article presents the results of research devoted to design and numerical calculation a low-flow high-head centrifugal pump with Barske-type impeller using computer simulation methods. main features fluid flow hydrodynamics, as well influence number geometry on energy cavitation characteristics pump, are found. focus is analysis end gap between blades casing, qualities pump. issue different ...
Automated method for exchange transfusion Sir, Philpott and Banerjee (Archives, 1972) are to be congratulated on their method of exchange transfusion using a two-channel Holter pump. Many have been interested in this technical problem, and the Holter pump provides an acceptable solution. The pumping rate of the machine is accurate to ±3%. More importantly, the discrepancy between the flow rates...
Recent advances in microfluidic devices put a high demand on small, robust and reliable pumps suitable for high-throughput applications. Here we demonstrate a compact, low-cost, directly attachable (clip-on) electroosmotic pump that couples with standard Luer connectors on a microfluidic device. The pump is easy to make and consists of a porous polycarbonate membrane and poly(3,4-ethylenedioxyt...
Transoesophageal echocardiography (TOE) was performed during closed chest cardiopulmonary resuscitation (CPR) in 18 subjects in cardiac arrest. Compression of all four cardiac chambers resulted in forward flow in the pulmonary and systemic circulations, retrograde pulmonary vein flow and incomplete mitral valve closure. Antegrade pulmonary vein flow and left ventricular filling occurred exclusi...
The present study concerns fluid-structure coupling phenomena occurring in a guide vane cascade of a pump-turbine scale model placed in the EPFL PF3 test rig. An advanced instrument set is used to monitor both vibrating structures and the surrounding flow. The paper highlights the interaction between vibrating guide vanes and the flow behavior. The pressure fluctuations in the stay vanes region...
The distortion of indicator dilution curves by catheter sampling systems is predictable from theoretic considerations based on laminar flow. Over a wide range of catheter and flow parameters, deductions can be made regarding distortion, by the arterial system or by sampling catheters, of indicator dilution curves coming from an idealized pump. A figure of merit for the sampling system is given ...
In this study, a new type of thin, compact, and light weighed diaphragm micro-pump has been successfully developed to actuate the liquid by the vibration of a diaphragm. The micro-diaphragm pump with two valves is fabricated in an aluminum case by using highly accurate CNC machine, and the cross-section dimension is 5mm×28mm. Both valves and diaphragm are manufactured from PDMS. The amplitude o...
Hemolysis in the GYRO centrifugal blood pump, under development at the Baylor College of Medicine, Houston, TX, is numerically predicted using the newly proposed tensor-based blood-damage model, as well as a traditional model. Three typical operating conditions for the pump are simulated with a special-purpose finite element-based flow solver, and a novel approach for tracing the pathlines in d...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید