نتایج جستجو برای: goldmann
تعداد نتایج: 1075 فیلتر نتایج به سال:
PURPOSE To determine if tangent visual fields gathered during assessment of superior visual field deficits caused by blepharoptosis and dermatochalasis offer good correlation to clinical exam in a time and cost efficient manner. METHODS Prospective, observational case series. Subjects included all patients referred to a single surgeon (CCN) who underwent surgical correction of blepharoptosis ...
OBJECTIVE To study the correlation and effect of sequential measurement of intraocular pressure (IOP) with Goldmann applanation tonometer (GAT), ocular response analyzer (ORA), dynamic contour tonometer (DCT), and Corvis ST. SETTING AND DESIGN Observational cross-sectional series from the comprehensive clinic of a tertiary eye care center seen during December 2012. METHODS One hundred and t...
OBJECTIVE To better define the concordance of visual loss in patients with nonarteritic anterior ischemic optic neuropathy (NAION). METHODS The medical records of 86 patients with bilateral sequential NAION were reviewed retrospectively, and visual function was assessed using visual acuity, Goldmann visual fields, color vision, and relative afferent papillary defect. A quantitative total visu...
BACKGROUND Blindness of a visual half-field (hemianopia) is a common symptom after postchiasmatic cerebral lesions. Although hemianopia severely limits activities of daily life, current clinical practice comprises no training of visual functions in the blind hemifield. OBJECTIVE To find out whether flicker sensitivity in the blind hemifield can be improved with intensive training, and whether...
PURPOSE To assess the intraocular pressure (IOP) and ocular rigidity (E) at 1, 3, 6 and 24 postoperative months in eyes that underwent LASIK. METHODS The IOP measured by Goldmann applanation tonometer (GAT) and by the 5.5 and 10 gm. weights of a standardized Schioetz tonometer (ST) and the E measured by differential tonometry (the 5.5 and 10 gm. of ST) were assessed before and after LASIK (at...
OBJECTIVE To investigate the influence of the stimulus parameters on perimetry at various distances and draw conclusions for the clinical exploration of nonorganic visual loss. METHODS Visual field testing using Goldmann kinetic perimetry was performed on 15 healthy volunteers. The I/1e isopter at 33 cm was compared to the I/1e, II/1e and I/2e isopters at 66 cm. The 0/1e isopter at 33 cm was ...
PURPOSE To compare intraocular pressure (IOP) between the new non-contact tonometer Corvis ST (CST), the Goldmann applanation tonometry (GAT) and Icare Pro rebound tonometer (PRO). METHODS A total of 178 eyes of 178 healthy subjects were selected for the study. Measurements of IOP were made in a random order with GAT, PRO and CST. Central corneal thickness (CCT) was determined by ultrasound p...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید