نتایج جستجو برای: heat exchanger system
تعداد نتایج: 2407355 فیلتر نتایج به سال:
Flash tank evaporation combined with a condensing heat exchanger can be used when heat exchange is required between two streams and where at least one of these streams is difficult to handle (in terms of solid particles content, viscosity, pH, consistency etc.). To increase the efficiency of heat exchange, a cascade of these units in series can be used. Heat transfer relationships in such a cas...
This work presents an experimental approach to study the refrigerant flow through capillary tube-suction line heat exchangers. Lateral heat exchanger performance with refrigerant HFC-134a was experimentally evaluated for a range of heat exchanger assemblies and operating conditions typically found in household refrigerators and freezers. Based on the resulting performance data base, the influen...
Recently, there have been many studies on dehumidifiers with a low flow rate of liquid desiccant, in which a plate-type heat exchanger with internal cooling is adopted. If the low flow rate of a liquid desiccant maintains a thin liquid film on the heat exchanger surface, heat and mass transfer performance would improve, the stability of the liquid film would increase, and there would be no entr...
0017-9310/$ see front matter 2010 Elsevier Ltd. A doi:10.1016/j.ijheatmasstransfer.2010.09.028 ⇑ Corresponding author. Tel.: +1 (765) 494 5705; fa E-mail address: [email protected] (I. Mud Hydrogen storage systems utilizing high-pressure metal hydrides (HPMHs) require a highly effective heat exchanger to remove the large amounts of heat released once the hydrogen is charged into the system...
OBJECTIVE To evaluate the possible changes in tidal volume, minute volume and respiratory rate caused by the use of a heat and moisture exchanger in patients receiving pressure support mechanical ventilation and to quantify the variation in pressure support required to compensate for the effect caused by the heat and moisture exchanger. METHODS Patients under invasive mechanical ventilation i...
In This paper uses an Attractive-Repulsive Particle Swarm Optimization (ARPSO) method for determining the optimal parameters of proportional-integral-derivative (PID) controller for temperature control of a shell and tube heat exchanger. Most of the heat exchange process is characteristic of nonlinear, large time delay and time varying. For such process it is very difficult to tune its controll...
Title of Dissertation: TRANSIENT MODELING OF TWO-STAGE AND VARIABLE REFRIGERANT FLOW VAPOR COMPRESSION SYSTEMS WITH FROSTING AND DEFROSTING Hongtao Qiao Doctor of Philosophy, 2014 Dissertation Directed By: Reinhard Radermacher, Professor Department of Mechanical Engineering This thesis presents the development of an advanced modeling framework for the transient simulation of vapor compression s...
We describe breakthrough results obtained in a feasibility study of a fundamentally new architecture for air-cooled heat exchangers. In conventional “fan-plus-finned-heat-sink” air-cooled heat exchangers, the primary physical limitation to performance (i.e. achieving low thermal resistance) is the boundary layer of motionless air that adheres to and envelops all surfaces of the heat exchanger. ...
Leakage in heat exchanger tubes can result in unreliable products and dangerous situations, which could cause great economic losses. Along with fast development of modern acoustic detection technology, using acoustic signals to detect leakage in heat exchange tube has been gradually accepted and considered with great potential by both industrial and research societies. In order to further advan...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید