نتایج جستجو برای: heat resistance coefficient

تعداد نتایج: 727105  

2017
Qingpu Li Lei Li Yongpan Hu Shengli Wu

The condensation heat transfer coefficient of R134a was experimentally studied inside two smooth and four micro-fin tubes. The working conditions and structural parameters of the test tubes were selected as the influencing factors, and the experiment was conducted under mass velocities of 400–1100 kg·m−2·s−1, condensation temperatures of 35–45 ◦C and water-testing Reynolds numbers of 8000–22,00...

An experimental investigation was conducted to study the average and the fully-developed heat (mass) transfer coefficients in a rectangular smooth duct and a duct with repeated-baffle blockages. The focus of attention in this work is the conventional correlation Nu / Nufd 1 + C / ( X / D ) for the average heat transfer coefficient. It was shown that for relatively short ducts, the coefficient C...

Journal: :journal of computational applied mechanics 0
seyed abdolkarim payambarpour school of mechanical engineering, college of engineering, university of tehran, tehran, iran hossein shokouhmand school of mechanical engineering, college of engineering, university of tehran, tehran, iran

heat and mass transfer, in this paper, is considered in one-row heat exchanger, that fins are hotter than air flow and water is added to fins. related governing equations are derived by analyzing a two-dimension model in a unique cell of a heat exchange. these equations are numerically solved by finite difference method. heat transfer and efficiency under partially wet surface are calculated by...

The optimal shape of a two dimensional turbulator above an isothermal flat plate is found by using numerical simulation. The turbulent boundary layer over the flat plate was disrupted at various situations by inserting a quadrilateral bar where the boundary layer thickness kept more than three times greater than the insert\'s height. As a result, the overall heat transfer coefficient of the wal...

2012
Y. P Du C. Y. Zhao Y. Tian Z. G. Qu

A newly simplified microstructure model of metal foams was carried out for flow boiling heat transfer in metal-foam filled tube. Fin analysis, heat transfer network and superposition correlation were adopted to obtain the equivalent heat transfer coefficient for flow boiling. Based on annular pattern, fluid can be divided into vapor region in the center of the tube and liquid region near the wa...

1999
R. Ramazashvili

I study a quantum Lifshitz point in a three-dimensional itinerant antiferromagnet, in particular the scaling of the Néel temperature, the correlation length, the staggered susceptibility, the specific heat coefficient and the resistivity. At low temperatures, the model is shown to have the inverse staggered susceptibility and the resistivity varying as T5/4, and the specific heat coefficient va...

Journal: :energy equipment and systems 0
behrang sajadi school of mechanical engineering, college of engineering, university of tehran, tehran, iran pedram hanafizadeh school of mechanical engineering, college of engineering, university of tehran, tehran, iran samar bahman school of mechanical engineering, college of engineering, university of tehran, tehran, iran ghazale hayati school of mechanical engineering, college of engineering, university of tehran, tehran, iran

plate heat exchangers are widely used in industries due to their special characteristics, such as high thermal efficiency, small size, light weight, easy installation, maintenance, and cleaning. the purpose of this study is to consider the effect of depth, angle, and pitch of hemispheric chevrons on the convective heat transfer coefficient and pressure drop. in the simulation of the heat exchan...

2015
M Kumar V K Yadav K K Srivastava

In this paper, we present experimental investigation of convective heat transfer characteristic in the inner tube fluid of miniature concentric double tube Hair-pin heat exchanger with constant heat flux. This work is carried out for distilled water and a mixture of distilled water and ethylene glycol (10%, 20% and 25% by volume) as heat transfer cold fluid flowing in inner tube to carry away h...

2017
Omer Sarfraz Christian Bach Omer SARFRAZ Christian K. BACH

This paper provides a review on the fouling mechanism and its effect onto the performance of finned tube heat exchangers in HVAC systems. Fouling tends to degrade the performance of heat exchangers by decreasing the heat transfer coefficient and increasing the air-side pressure drop across the heat exchangers. Air side fouling depends on a number of factors on the air side, including type and c...

2013
B. Wetton

A theoretical model for nanofluid flow, including Brownian motion and thermophoresis, is developed and analysed. Standard boundary layer theory is used to evaluate the heat transfer coefficient near a flat surface. The model is almost identical to previous models for nanofluid flow which have predicted an increase in the heat transfer with increasing particle concentration. In contrast our work...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید