نتایج جستجو برای: hip resurfacing function

تعداد نتایج: 1272080  

2014
Jonathan RB Hutt Martin Lavigne

Total hip arthroplasty (THA) is the gold standard in the treatment of degenerative hip disease, especially in the older patient. Concerns regarding the higher levels of failure of traditional implants in younger, more active patients have led to a search for alternative arthroplasty techniques. Hip resurfacing (HR) is one of these alternatives. When compared with THA, HR has some theoretical ad...

Journal: :The Journal of bone and joint surgery. British volume 2011
D J Langton S S Jameson T J Joyce J N Gandhi R Sidaginamale P Mereddy J Lord A V F Nargol

There is widespread concern regarding the incidence of adverse soft-tissue reactions after metal-on-metal (MoM) hip replacement. Recent National Joint Registry data have shown clear differences in the rates of failure of different designs of hip resurfacing. Our aim was to update the failure rates related to metal debris for the Articular Surface Replacement (ASR). A total of 505 of these were ...

Journal: :The Journal of bone and joint surgery. British volume 2011
D J Langton T J Joyce S S Jameson J Lord M Van Orsouw J P Holland A V F Nargol K A De Smet

We sought to establish the incidence of joint failure secondary to adverse reaction to metal debris (ARMD) following metal-on-metal hip resurfacing in a large, three surgeon, multicentre study involving 4226 hips with a follow-up of 10 to 142 months. Three implants were studied: the Articular Surface Replacement; the Birmingham Hip Resurfacing; and the Conserve Plus. Retrieved implants underwen...

Journal: :The Journal of bone and joint surgery. British volume 2010
A J Shimmin W L Walter C Esposito

The survivorship of contemporary resurfacing arthroplasty of the hip using metal-on-metal bearings is better than that of first generation designs, but short-term failures still occur. The most common reasons for failure are fracture of the femoral neck, loosening of the component, osteonecrosis of the femoral head, reaction to metal debris and malpositioning of the component. In 2008 the Austr...

2012
Florian Schmidutz Lorenz Wanke-Jellinek Volkmar Jansson Andreas Fottner Farhad Mazoochian

INTRODUCTION Suitable treatment of early failure of total hip replacement is critical in younger patients, as bone stock is lost and the functional outcome is impaired. CASE PRESENTATION We report the case of a 56-year-old Caucasian woman with early failure of hip resurfacing arthroplasty. While revision is usually performed with a conventional hip implant, this case report describes for the ...

Journal: :The Journal of bone and joint surgery. British volume 2003
D Cumming M J F Fordyce

We describe a patient who sustained a peri-prosthetic fracture of the femoral neck two weeks after undergoing a resurfacing procedure for osteoarthritis of the hip. The fracture was minimally displaced and a satisfactory outcome was obtained following conservative treatment.

Journal: :The Journal of bone and joint surgery. British volume 2010
K De Smet P A Campbell H S Gill

We report the consensus of surgical opinions of an international faculty of expert metal-on-metal hip resurfacing surgeons, with a combined experience of over 18,000 cases, covering required experience, indications, surgical technique, rehabilitation and the management of problematic cases.

2011
José MH Smolders Annemiek Hol Willard J Rijnberg Job LC van Susante

BACKGROUND Modern metal-on-metal hip resurfacing was introduced as a bone-preserving method of joint reconstruction for young and active patients; however, the large diameter of the bearing surfaces is of concern for potentially increased metal ion release. PATIENTS AND METHODS 71 patients (< 65 years old) were randomly assigned to receive either a resurfacing (R) hip arthroplasty (n = 38) or...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید