Michael Shapiro Sam Hanon Paul Schweitzer

This article describes an interesting case of automated implantable cardioverter defibrillator (AICD) extrusion fifteen months after implantation. The case report is followed by a discussion of the causes and treatment of skin erosion following pacemaker/AICD insertion.

Journal: :Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2015
Benjamin J Pang S Serge Barold Harry G Mond

Damage to the coronary arteries and related structures from pacemaker and implantable cardioverter-defibrillator lead implantation is a rarely reported complication that can lead to myocardial infarction and pericardial tamponade that may occur acutely or even years later. We summarize the reported cases of injury to coronary arteries and related structures and review the causes of troponin ele...

Journal: :CoRR 2015
Houssam Abbas Kuk Jin Jang Zhihao Jiang Rahul Mangharam

Ventricular Fibrillation is a disorganized electrical excitation of the heart that results in inadequate blood flow to the body. It usually ends in death within seconds. The most common way to treat the symptoms of fibrillation is to implant a medical device, known as an Implantable Cardioverter Defibrillator (ICD), in the patient’s body. Modelbased verification can supply rigorous proofs of sa...

2016
Mohamed Teleb Nabeel Badri

The second ECG recorded supraventricular tachycardia at the time his hemodynamic status deteriorated and decision was made to perform electrical cardioversion with 120 Joules of biphasic synchronized direct current with follow up ECG that showed atrial paced rhythm (Figure 1B). His condition improved and started on amiodarone 200 mg, anticoagulation, and subsequent follow up for ICD reprogrammi...

2011
Johannes B. van Rees Jan Willem Borleffs Martin J. Schalij

Results A total of 1,544 ICD patients (79% male, age 61 13 years) were included in the analysis. During the follow-up period of 41 18 months, 13% experienced 1 inappropriate shocks. The cumulative incidence steadily increased to 18% at 5-year follow-up. Independent predictors of the occurrence of inappropriate shocks included a history of atrial fibrillation (hazard ratio [HR]: 2.0, p 0.01) and...

Journal: :Revista espanola de cardiologia 2014
Jesús Almendral Marta Pombo Jesús Martínez-Alday José M González-Rebollo Enrique Rodríguez-Font José Martínez-Ferrer Eduardo Castellanos F Javier García-Fernández Francisco Ruiz-Mateas

This report discusses a selection of the most relevant articles on cardiac arrhythmias and pacing published in 2013. The first section discusses arrhythmias, classified as regular paroxysmal supraventricular tachyarrhythmias, atrial fibrillation, and ventricular arrhythmias, together with their treatment by means of an implantable cardioverter defibrillator. The next section reviews cardiac pac...

Journal: :Journal of cardiovascular electrophysiology 2007
Jennifer Cowger Matthews Daphne Betley Fred Morady Frank Pelosi

An increasing number of patients have a coexisting implantable cardioverter defibrillator (ICD) and left ventricular assist device (LVAD) to treat ventricular arrhythmias and refractory heart failure, respectively. To date, there have been no published reports of negative interactions between these devices that have impacted appropriate ICD or LVAD function. In this case report, we describe a p...

2016
David J. Whellan

Methods The PARTNERS HF (Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients With Heart Failure) was a prospective, multicenter observational study in patients receiving cardiac resynchronization therapy (CRT) implantable cardioverter-defibrillators. HF events were independently adjudicated. A combined HF device diagnostic algorithm was developed o...

2018
Carmen Adduci Francesca Palano Pietro Francia

The trans-venous implantable cardioverter defibrillator (TV-ICD) is effective in treating life-threatening ventricular arrhythmia and reduces mortality in high-risk patients. However, there are significant short- and long-term complications that are associated with intravascular leads. These shortcomings are mostly relevant in young patients with long life expectancy and low risk of death from ...

2017
Syeda Atiqa Batul Brian Olshansky John D Fisher Rakesh Gopinathannair

Ventricular arrhythmias are an important cause of cardiovascular morbidity and mortality, particularly in those with structural heart disease, inherited cardiomyopathies, and channelopathies. The goals of ventricular arrhythmia management include symptom relief, improving quality of life, reducing implantable cardioverter defibrillator shocks, preventing deterioration of left ventricular functi...

نمودار تعداد نتایج جستجو در هر سال