نتایج جستجو برای: liquid scintillation
تعداد نتایج: 221859 فیلتر نتایج به سال:
The scintillation efficiency of liquid xenon for nuclear recoils has been measured to be nearly constant in the recoil energy range from 140 keV down to 5 keV. The average ratio of the efficiency for recoils to that for gamma-rays is found to be 0.19±0.02. PACS codes: 29.40.Mc, 78.70.-g, 78.60.-b, 95.35.+d
In radioimmunoassays and radioassays for various constituents of serum, color quenching is a source of error when liquid-scintillation methods are used in samples that contain hemolyzed blood and samples from jaundiced patients. A quench correction can be made by using the External Standard Channels Ratio method and normalizing the ratios, or, alternatively, by chemical decolorization with tetr...
EVALUATiON OF A new drug includes analysis of its tissue distribution. We have developed an improved method for solubilizing tissues that is not only rapid, but results in a homogeneous sample for counting. We had found that organs rich in connective tissue (heart, lung, skeletal muscle, urinary bladder, stomach, and intestinal wall) could not be completely disrupted by conventional techniques ...
Developments of liquid-scintillation counting as a practical method for the assay of radioisotopes in biological samples followed work by Reynolds, Harrison & Salvini (1950) and Kailmann & Furst (1950). Reviews of progress and developments in liquid-scintillation counting have been given by Davidson & Fiegelson (1957) and Bell & Hayes (1958). Guinn (1958) and Stitch (1959) have reviewed the adv...
The production rate is 7.5 kg isotope C-14 yearly. The C-14 concentration stays approximately constant due to rapid mixing of the atmosphere, although the cosmic intensity is higher at the poles due to the deflection of charged cosmic particles along the magnetic field lines of the earth (corresponding to neutron intensities in the ratio 5:1 at the poles and the equator, respectively). Conseque...
The need for fast, accurate and high resolution dosimetric quality assurance in radiation therapy has been outpacing the development of new and improved 2D and 3D dosimetry techniques. This paper summarizes the efforts to create a novel and potentially very fast, 3D dosimetry method based on the observation of scintillation light from an irradiated liquid scintillator volume serving simultaneou...
PURPOSE The goal of this research was to design a liquid scintillation dosimeter that could be used forrelative dosimetry of linear accelerator fields. The project emphasized minimization of cost and ease of use. METHODS The scintillator that was used in this research was BETAMAX- ES scintillation cocktail from MPBiomedical. This particular scintillator was selected due to its relatively high...
Two novel maltol-based ionic liquids, namely [A336][Mal] and [C101][Mal], were synthesized as potential extracting agents for radionuclides from water. These two room temperature task-specific ionic liquids could be easily prepared by anion metathesis starting from commercially available materials. The isolated compounds were characterized by standard analytical methods. Their application as ex...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید