نتایج جستجو برای: locking plate

تعداد نتایج: 83531  

Journal: :Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca 2013
S B Hunt R E Buckley

Locking plates are important tools in the orthopedic surgeon’s armamentarium. They have demonstrated tremendous effectiveness in dealing with challenging fractures yet the specific indications and techniques for their use is still the subject of considerable debate (2, 41). Inappropriate application of standard orthopedic operative principles may compromise patient outcome, frustrate surgeons, ...

Journal: :the archives of bone and joint surgery 0
prakash jayakumar oxford university massachusetts general hospital and harvard medical school david ring hand and upper extremity service. massachusetts general hospital and harvard medical school.

anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. the distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

Journal: :archives of trauma research 0
kavin khatri department of orthopaedics, ggs medical college faridkot, baba farid university of health sciences, faridkot, india; department of orthopaedics, ggs medical college faridkot, baba farid university of health sciences, faridkot, india. tel: +91-8743878077 vijay sharma department of orthopaedics, jai prakash narayan apex trauma centre, all india institute of medical sciences, (aiims), new delhi, delhi, india kamran farooque department of orthopaedics, jai prakash narayan apex trauma centre, all india institute of medical sciences, (aiims), new delhi, delhi, india vivek tiwari department of orthopaedics, jai prakash narayan apex trauma centre, all india institute of medical sciences, (aiims), new delhi, delhi, india

conclusions the use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications. objectives this study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. patients and methods we reviewed 23 unstable ...

Journal: :Journal of orthopaedic surgery 2005
Frankie Leung

satisfactory functional level, which may be crucial to elderly patients? Addressing these issues, various locking screws and implants are rapidly gaining popularity for these patients in certain regions. Such implants come with screws that directly engage the plate to create fixedangle bolts, thus offering better fixation in osteoporotic bone. Volar application of such locking implants can be u...

Journal: :Psychiatria Danubina 2014
Fabijan Cukelj Josip Knežević Janoš Kodvanj Ante Bandalović Marko Ostojić Kanito Bilan Arsen Pavić

BACKGROUND Proximal humerus fractures are represented as 4-5% of all fractures, with incidence notably growing with age. Since surgical internal fixation in treatment of proximal humeral fractures is used, fractures of osteoporotic bone and choice of plate for their osteosynthesis represent particular problem. The aim of the study was to test two locking plates: Philos plate with locking screws...

Journal: :Orthopaedics & traumatology, surgery & research : OTSR 2011
M Ehlinger D Brinkert J Besse P Adam Y Arlettaz F Bonnomet

The incidence of femoral fracture on hip prosthesis is increasing. Plate fixation is the method of choice when the prosthesis is stable. In fracture with proximal extension, the quality of the bone fixation is critical and, despite the development of anatomic plates, may be endangered when there are too few proximal screws. To resolve this issue, we recommend using a reversed LCP™ anatomic dist...

2016
Jeong-Ku Ha Chul Hyun Yeom Ho Su Jang Han Eui Song Sung Jae Lee Kang Hee Kim Kyu Sung Chung Mahendar Gururaj Bhat Jin Goo Kim

BACKGROUND The purpose of this study was to analyze biomechanical properties of a novel wedge locking plate in medial open wedge high tibial osteotomy (OWHTO) in a porcine tibial model. METHODS A uniform 8-mm OWHTO was performed in 12 porcine tibiae. Six of them were subsequently fixed with the plate without a wedge, whereas the other 6 were additionally reinforced with a metal wedge of 8 mm....

Journal: :The archives of bone and joint surgery 2017
Rajesh Govindasamy Saravanan Kasirajan Tushar Doke

Background The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higher rate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of these fractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal end clavicle fractures treated with superior anterior...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید