نتایج جستجو برای: mv photon beam

تعداد نتایج: 199565  

1998
MARTIN J. BUTSON PETER K. N. YU PETER E. METCALFE

ÐMeasurement of lepton contamination is achieved across a radiotherapy photon beam and peripheral doses using radiochromic ®lm. An extrapolation technique is used where several layers are suspended in air to measure incident contamination without the e€ects of phantom scatter. Surface dose was measured as 11% of Dmax for 6 MV beams at central axis and 9% for 10 MV photons for a 10 10 cm ®eld si...

Journal: :iranian journal of radiation research 0
t. siji cyriac department of physics, noorul islam centre for higher education, kumaracoil, thuckalay, kanyakumari district, 629 180, tamilnadu, india m.m. musthafa department of physics, university of calicut, thenhipalam, malappuram, 673 635, kerala, india r. ganapathi raman department of physics, noorul islam centre for higher education, kumaracoil, thuckalay, kanyakumari district, 629 180, tamilnadu, india k. abdul haneefa infn and department of physics, university of torino, via p. giuria, 10125, torino, italy saju bhasi department of radiation physics, regional cancer center, trivandrum, 695 011 , kerala, india

background: the present work aims to study the out-of-field photon calculation accuracy of a commercial treatment planning system (tps), oncentra, for three-dimensional conformal radiotherapy (3d-crt) and intensity modulated radiation therapy (imrt) treatment techniques from elekta synergy medical linear accelerator. materials and methods: accuracy of individual out-of-field dose components was...

A. Ebrahimzadeh Pezeshki, M. Mohammadi, S. Abdollahi, Z. Alizadeh,

Background: In order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. When the calibration procedure is performed for a reference dosimeter in the 60Co beam of a Secondary Standard Dosimetry Laboratory (SSDL), the total uncertainty in absorbed dose to water (Dw) is estimated to be approximately 1.5%. This study attempts...

Journal: :Physics in medicine and biology 2000
M Fippel F Nüsslin

Current clinical experience in radiation therapy is based upon dose computations that report the absorbed dose to water, even though the patient is not made of water but of many different types of tissue. While Monte Carlo dose calculation algorithms have the potential for higher dose accuracy, they usually transport particles in and compute the absorbed dose to the patient media such as soft t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید