نتایج جستجو برای: pacemaker implantation

تعداد نتایج: 82599  

2017
Bin-Feng Mo Qiu-Fen Lu Shang-Biao Lu Yu-Quan Xie Xiang-Fei Feng Yi-Gang Li

BACKGROUND The CHA2DS2-VASc score is used clinically for stroke risk stratification in patients with atrial fibrillation (AF). We sought to investigate whether the CHA2DS2-VASc score predicts stroke and death in Chinese patients with sick sinus syndrome (SSS) after pacemaker implantation and to evaluate whether the predictive power of the CHA2DS2-VASc score could be improved by combining it wit...

Journal: :Circulation journal : official journal of the Japanese Circulation Society 2007
Tien-En Chen Chun-Chieh Wang Ming-Shyan Chern Jaw-Ji Chu

Transthoracic 2-dimensional (D) echocardiography (echo) is often used to assess tricuspid regurgitation (TR) after implantation of permanent pacemakers. However, its ability to define the precise anatomical relationship between the tricuspid valve and the pacemaker lead is quite limited. This report presents a 58-year-old male with aggravation of TR after pacemaker implantation for heart block....

Journal: :Journal of the Chinese Medical Association : JCMA 2004
Meng-Cheng Chiang Wei-Hsian Yin Hsu-Lung Jen Mason Shing Young

Electrode instability and displacement have been reported in patients who underwent pacemaker implantation via persistent left superior vena cava. An active-fixation system, and sometimes epicardial pacing, is necessary to maintain pacing stability. We report the case of a 76-year-old man with a left superior vena cava who required dual-chamber permanent pacing. Passive-fixation atrial and vent...

Journal: :Pacing and clinical electrophysiology : PACE 2010
Nuno Dias Ferreira Daniel Caeiro Luís Adão Marco Oliveira Helena Gonçalves José Ribeiro Madalena Teixeira Aníbal Albuquerque João Primo Pedro Braga Lino Simões Vasco Gama Ribeiro

BACKGROUND Previous reports have suggested the occurrence of cardiac conduction disorders and permanent pacemaker (PPM) requirement after transcatheter aortic valve implantation (TAVI). Based on a single-center experience, we aim to assess the incidence of postprocedural conduction disorders, need for PPM, and its determinants after TAVI with a self-expanding bioprosthesis. METHODS From Augus...

Journal: :Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology 2014
Bruno Tereno Valente José M Conceição Manuel Nogueira da Silva Mário M Oliveira Pedro S Cunha Ana Lousinha Ana Galrinho Rui C Ferreira

The classic transvenous implantation of a permanent pacemaker in a pectoral location may be precluded by obstruction of venous access through the superior vena cava or recent infection at the implant site. When these barriers to the procedure are bilateral and there are also contraindications or technical difficulties to performing a thoracotomy for an epicardial approach, the femoral vein, alt...

Journal: :Polskie Archiwum Medycyny Wewnetrznej 2015
Andrzej Ząbek Barbara Małecka Igor Tomala Paweł Matusik Krzysztof Boczar Jacek Lelakowski

89 coaptation, the patient was scheduled for tricuspid valve annuloplasty with concurrent implantation of an epicardial ventricular lead and pacemaker. The operation was preceded by the transvenous extraction of the old ventricular lead. Due to advanced tricuspid valve lesions, a decision was made during surgery to perform artificial tricuspid valve implantation (Medtronic ATS 33 mm). Simultane...

Journal: :Revista espanola de cardiologia 2002
Carmen Garrote María Luisa Fidalgo Ignacio Iglesias-Garriz Félix Corral Jorge Silvestre Ramón García-Calabozo

Tricuspid stenosis related to endocardial pacemaker leads is uncommon. We report the case of a patient with severe tricuspid stenosis documented 15 years after the implantation of a permanent DDD pacemaker for symptomatic congenital heart block. The atrial and ventricular leads both had a loop at the level of the tricuspid valve that may have caused endothelial damage and, eventually, tricuspid...

Journal: :Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2014
Giacomo Mugnai Gabriele Pesarini Corrado Vassanelli

Twoweeks after dual-chamber pacemaker implantation, a 51-year-oldman presented typical signs of pacemaker pocket infection. Device and leadswere explanted.As the local pain persisted and even extended to the left clavicle, amagnetic resonancewas performed and acute osteomyelitis of the left clavicle was diagnosed. Nine months later, a nearly complete resolution of the osteomyelitic focus was ob...

2017
Serdar Bozyel Tolga Aksu Tumer Erdem Guler Kazım Serhan Ozcan Mujdat Aktas

The twiddler syndrome is an uncommon cause of pacemaker malfunction, in which twisting or rotating of the device in its pocket results in lead retraction or coiling and subsequent malfunction of an implanted devices such as a pacemaker, an implantable cardioverter-defibrillator (ICD), cardiac resynchronization therapy (CRT).  This report describes a rare case of twiddler syndrome after implant...

2016
Arun Gopi

Transvenous cardiac pacemakers definitely improve quality of life and reduce mortality in at-risk patients, but they are associated with several potential device-related complications. Approximately 10% of patients experience complications related to transvenous implantation of the pacemaker. These may be attributable to either the pulse generator (hematoma, skin breakdown, pocket infection) or...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید