نتایج جستجو برای: partial pressure sensor

تعداد نتایج: 801801  

Journal: :Optics express 2012
X Zhao J M Tsai H Cai X M Ji J Zhou M H Bao Y P Huang D L Kwong A Q Liu

This paper reports a nano-opto-mechanical pressure sensor based on nano-scaled ring resonator. The pressure is measured through the output spectrum shift which is induced via mechanical deformation of the ring resonator. The sensitivity as high as 1.47 pm/kPa has been experimentally achieved which agrees with numerical prediction. Due to the strong variation of sensitivity with different ring r...

2010
Katsuyuki Uematsu Hiroko Tanaka Hirofumi Kato

Exhaust gas regulations for motor vehicles are becoming stricter year-after-year, and as internal combustion engines are being made more efficient and their exhaust gas reduced, there is increased demand for pressure sensing in the exhaust systems of diesel engine vehicles. Applying a single-chip semiconductor pressure sensor fabricated by a CMOS process, which has been successfully used for ma...

2012
Weizhong Wang Yulong Zhao Yafei Qin

An integrated multifunction micro-sensor for three-dimensional micro-force precision measurement under different pressure and temperature conditions is introduced in this paper. The integrated sensor consists of three kinds of sensors: a three-dimensional micro-force sensor, an absolute pressure sensor and a temperature sensor. The integrated multifunction micro-sensor is fabricated on silicon ...

2009
H. Y. Fu Chuang Wu M. L. V. Tse Lin Zhang H. Y. Tam Bai-Ou Guan C. Lu P. K. A. Wai

We experimentally demonstrate a high pressure sensor based on a polarization-maintaining photonic crystal fiber (PMPCF) with Sagnac loop configuration for downhole application. The pressure sensitivity of the proposed sensor is 4.21 nm/MPa and 3.27 nm/MPa at ~1320 nm and ~1550 nm respectively. High pressure measurement up to 20 MPa has been achieved in our experiment. The sensor also shows redu...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2008
samaneh razzaghi riyaz kharrat davood rashtchian shapour vossoughi soheil saraji

in this work, the potential of auto-ignition of heavy oil during in-situ combustion (isc) process was studied. kinetic studies were carried out using thermo gravimetric analyzer (tga), differential scanning calorimetry (dsc) and accelerating rate calorimetric (arc) techniques. effects of oxygen partial pressure, reservoir pressure and clay on auto ignition condition were investigated on a numbe...

2017
Iryna Khodasevych Suresh Parmar Olga Troynikov

Flexible pressure sensors are increasingly being used in medical and non-medical applications, and particularly in innovative health monitoring. Their efficacy in medical applications such as compression therapy depends on the accuracy and repeatability of their output, which in turn depend on factors such as sensor type, shape, pressure range, and conformability of the sensor to the body surfa...

2015
Vitalij Kotovskyi Yurii Dzhezherya Aleksandr Dovzhenko Nikolaj Visniakov Andzela Sesok

In the paper, an opportunity for the development of multichannel transcutaneous raster matrixes for sensors of oxygen on the basis of an electrochemical cell sensor is described. An analysis of the influence of heat sources on the distribution of the temperature pattern of a raster matrix for sensors of oxygen had been carried out, and their optimum configuration had been found. The application...

2010
Lúcio Honório de Carvalho Júnior Luiz Fernando Machado Soares Matheus Braga Jacques Gonçalves Tiago Pinto de Oliveira Gomes Juraci Rosa de Oliveira Mauro Gualberto Coelho Rogério Luciano dos Santos Marco Antônio Percope de Andrade Guilherme de Lima e Silva Eduardo Nilo Vasconcelos Novais

UNLABELLED To evaluate whether, by using an arthropump (irrigation equipment with pressure sensor), pneumatic tourniquet use could interfere with the duration of surgery, recovery of movement and joint volume in patients who underwent knee videoarthroscopy for partial meniscectomy. METHODS 103 patients divided randomly into two groups regarding use or nonuse of a pneumatic tourniquet were eva...

2006
Juncheng Xu Ira Jacobs Ahmad Safaai-Jazi Yilu Liu Gary R. Pickrell Guy J Indebetouw

(Abstract) Pressure measurements are required in various industrial applications, including extremely harsh environments such as turbine engines, power plants and material-processing systems. Conventional sensors are often difficult to apply due to the high temperatures, highly corrosive agents or electromagnetic interference (EMI) noise that may be present in those environments. Fiber optic pr...

2016
Yonggang Jiang Jian Li Zhiwen Zhou Xinggang Jiang Deyuan Zhang

Single-crystal silicon carbide (SiC)-based pressure sensors can be used in harsh environments, as they exhibit stable mechanical and electrical properties at elevated temperatures. A fiber-optic pressure sensor with an all-SiC sensor head was fabricated and is herein proposed. SiC sensor diaphragms were fabricated via an ultrasonic vibration mill-grinding (UVMG) method, which resulted in a smal...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید