Journal: :journal of biomedical physics and engineering 0
m. dehghan master student of physics, department of physics, yazd university, yazd, iran h. mokhtari assistant professor of physics, department of physics, yazd university, yazd, iran f. bouzarjomehri associate professor of medical physics, shahid sadoughi university of medical sciences, yazd, iran

background: over recent decades, modern protocols of external beam radio¬therapy and radiation techniques such as intensity-modulated radiotherapy (imrt) have been developed. these methods are extremely sensitive to errors in treatment delivery, so that it is essential to apply a high resolution 3d dosimetry system that has high sensitivity and is capable of measuring and verifying the complex ...

2012
Yoichi Watanabe Naoki Hayashi

Some dosimeters require a relationship between detector signal and delivered dose. The relationship (characteristic curve or calibration equation) usually depends on the environment under which the dosimeters are manufactured or stored. To compensate for the difference in radiation response among different batches of dosimeters, the measured dose can be scaled by normalizing the measured dose t...

2017
Rahim Sabbaghizadeh Roslinda Shamsudin Najmeh Deyhimihaghighi Arman Sedghi

In the present study, the normoxic polyacrylamide gelatin and tetrakis hydroxy methyl phosphoniun chloride (PAGAT) polymer gel dosimeters were synthesized with and without the presence of silver (Ag) nanoparticles. The amount of Ag nanoparticles varied from 1 to 3 ml with concentration 3.14 g/l, thus forming two types of PAGAT polymer gel dosimeters before irradiating them with 6 to 25 Gy produ...

F. Bouzarjomehri, H. Mokhtari M. Dehghan

Background: Over recent decades, modern protocols of external beam radioÂ‌therapy and radiation techniques such as intensity-modulated radiotherapy (IMRT) have been developed. These methods are extremely sensitive to errors in treatment delivery, so that it is essential to apply a high resolution 3D dosimetry system that has high sensitivity and is capable of measuring and verifying the complex...

2010
Shingo Maeda Yusuke Hara Ryo Yoshida Shuji Hashimoto

Many kinds of stimuli-responsive polymer and gels have been developed and applied to biomimetic actuators or artificial muscles. Electroactive polymers that change shape when stimulated electrically seem to be particularly promising. In all cases, however, the mechanical motion is driven by external stimuli, for example, reversing the direction of electric field. On the other hand, many living ...

Journal: :NIPPON GOMU KYOKAISHI 1993

Hasan Nedaie Hossein Hasani, Mahmood Allahverdi Mohammad Hasan Zahmatkesh Saeid Bagheri Sajad Mirzaie

Introduction: In radiotherapy, methods of treatment planning are becoming increasingly more complicated. This requires verification of the doses delivered to increasingly smaller and more precise regions. Radiotherapy techniques are continuously employing smaller and smaller field sizes to deliver tighter radiation doses with higher therapeutic ratios, generating interest among researchers to p...