OBJECTIVES Arterial pulse pressure respiratory variation is a good predictor of fluid response in ventilated patients. Recently, it was shown that respiratory variation in arterial pulse pressure correlates with variation in pulse oximetry plethysmographic waveform amplitude. We wanted to evaluate the correlation between respiratory variation in arterial pulse pressure and respiratory variation...
To compare pulse oximetry measurement bias between infants with hypoxemia with either dark skin or light skin with Masimo Radical 7 and Nellcor Oximax. There was no significant difference in systematic bias based on skin pigment for either oximeter.
To expand applicability of pulse oximetry in low-acuity ambulatory settings, the impact of motion on extracted parameters as saturation (SpO2) and pulse rate (PR) needs to be reduced. We hypothesized that sensor motion relative to the skin can be used as an artifact reference in a correlation canceller to reduce motion artifacts in photoplethysmograms (PPGs), in order to improve SpO2 and PR mea...
PURPOSE OF REVIEW This article reviews the development of novel reflectance pulse oximetry sensors for the esophagus and bowel, and presents some of the techniques used to analyze the waveforms acquired with such devices. RECENT FINDINGS There has been much research in recent years to expand the utility of pulse oximetry beyond the simple measurement of arterial oxygen saturation from the fin...
106:1189 –94 35. Golparvar M, Naddafnia H, Saghaei M: Evaluating the relationship between arterial pressure changes and indices of pulse oximetric plethysmography. Anesth Analg 2002; 95:1686–90 36. Natalini G, Rosano A, Franceschetti ME, Facchetti P, Bernardini A: Variations in arterial blood pressure and photoplethysmography during mechanical ventilation. Anesth Analg 2006; 103:1182– 8 37. Sol...
In this research, the incremental slitting method was employed to determine throughthickness residual stress profile of a carbon/epoxy laminate. The method involves measuring strains at the back surface of the stressed specimen, while a narrow slit is cut by a CNC milling machine progressively from the top surface of the specimen. "Pulse Method" was selected as the computational approach for th...
Polarization for Au/Pb(Zr Ti )O /YBa Cu O ferroelectric capacitor has been studied and measured by pulse method. A sequence of pulses with amplitudes varying from 0 to 10 volts in 2 volt steps is applied and a conventional polarization curve is obtained by integrating the charge flow from the polarization switching induced by the voltage ramp. A value of 25?C/cm2 is measured for the satur...
The MediWatch is a wrist-mounted noninvasive blood pressure monitor designed to capture the radial pulse waveform using arterial tonometry and yield blood pressure measurements when the waveform is calibrated. An early prototype of this monitor uses a pulse-sensing system with a cylindrical plunger to applanate the radial artery. This prototype was evaluated against simulated blood pressure gen...