نتایج جستجو برای: radio chromic dosimeter presage
تعداد نتایج: 104665 فیلتر نتایج به سال:
Naphthalene diimides have electrochromic applications due to their highly stable dark reduced state along with a transparent colourless neutral state. Here we show the morphology of aggregated structures at different pHs has greater influence on chromic properties than chemical structure.
مقدمه: در طی سال های اخیر، توسعه تکنیک های پرتو درمانی از قبیل imrt ، igrt و srs نیاز به ابزارهای اندازه گیری سه بعدی دز را آشکارتر کرده است. مطالعات زیادی توسط محققین برای توسعه روشهای دزیمتری سه بعدی انجام شده است. امروزه روش پلیمر ژل دزیمتری، به کمک روشهای تصویربرداری، امکان اندازه گیری توزیع سه بعدی دز را فراهم کرده است. اما این روش با محدودیت هایی مواجهه است. اخیراً نوعی دزیمتر پلیمری شفاف ...
The purpose of this study was to evaluate dependence of PAGAT polymer gel dosimeter 1/T2 on different electron and photon energies for a standard clinically used Co therapy unit and an electa linear accelerator.Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2(1/T2) was determined to be 4.5% N,N'-methylen-bis-acrylamide(bis), 4.5% acrylamid(AA), 5% gelat...
In the European Community Respiratory Health Study (ECRHS), airway responsiveness to methacholine was determined using the Mefar dosimeter protocol. Elsewhere, the 2-min tidal breathing method has become the preferred standardized method. The relationship between measurements of responsiveness by these two methods is not well established. This study measured airway responsiveness to methacholin...
Polysulphone has been widely used as a dosimeter to quantify personal solar UV exposures to humans during normal daily activities. In summer at sub-tropical and tropical latitudes, the dynamic range for UV exposures allows the use of the polysulphone to measure solar UV over periods of approximately three to six hours. The use of mesh as a filter over the polysulphone has been previously report...
Spectrophotometric measurements of the Fricke–gelatin–xylenol orange (FGX) gel dosimeter demonstrated reproducible linear dose response up to 25Gy. However, oxidation processes continue post-irradiation, affecting the response of this dosimetry system. Additional oxygenation during preparation increases the sensitivity of the gel but does not improve the auto-oxidation stability of the dosimete...
AIM This study was conducted to evaluate and compare the tissue reactivity and suture handling characteristics of chromic gut, silk, and 'jimat' suture materials in cat thigh muscle. MATERIALS AND METHODS This experimental study was conducted from November, 2013 to April, 2014 in Kombolcha Animal Diseases Survey, Research and Diagnostic Laboratory, Kombolcha, Ethiopia. A total of 36 local bre...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید