Cardiac computed tomography (CT) has been shown a non-invasive tool with high diagnostic accuracy for the detection of coronary arterial stenosis [1]. However, the hemodynamic significance of many lesions is uncertain by Cardiac CT. Furthermore, the presence of calcified atherosclerotic plaque reduces the ability to differentiate significant stenosis from non-obstructive plaque. Thus, invasive ...
Introduction The idea of computed tomography (CT) was first introduced in the 1960’s with the development of modern computer technology. The first scanners were commercially available in the 1970’s, and grew in popularity through the 1980’s. The innovation of helical-scanning CT produced true volume imaging with sub-millimeter resolution. CT can be used for both anatomical as well as pathologic...
conclusion scout views may be useful in determining dose and image quality in ct scanning; however, it is necessary to first determine the most appropriate scout view for ct scans. background while using the automatic exposure control technique in computed tomography (ct), the scout view determines the radiation dose for the ct scan by taking anatomical morphology into consideration. objectives...
Applying micro-computed tomography for porosity analysis of polypropylene modified with microspheres
Porosity of polypropylene samples was investigated by applying X-ray micro-computed tomography (micro-CT), which is getting more and popular as a non-destructive method. Microspheres were applied blowing agent at three concentrations: 3%, 6% 9% weight. Tensile testing specimens obtained injection molding technology its central, measuring part examined micro – CT. Results compared to porosity ca...
Gliomas account for almost 80% of primary malignant brain tumors in adults. Magnetic Resonance imaging (MRI) is still the gold standard for diagnosis of brain tumors and brain 99mTc-tetrofosmin Single Photon Emission Computed Tomography (99mTc-tetrofosmin-SPECT) has been established as a useful tool for their evaluation. Fluorine-18–2-fluoro-2-deoxy-d-glucose positron emi...
Current computed tomography (CT) scanners, including micro-CT scanners, utilize a point x-ray source. As we target higher and higher spatial resolutions, the reduced x-ray focal spot size limits the temporal and contrast resolutions achievable. To overcome this limitation, in this paper we propose to use a line-shaped x-ray source so that many more photons can be generated, given a data acquisi...
PURPOSE To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. MATERIALS AND METHODS Tubes containing solutions with different concentrations of K2HPO4 were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT...
This paper presents the results of the CT-STARR (CT-Surface Texture for Additive Round Robin) interlaboratory comparison. The study compares the results obtained for the extraction of areal surface texture data per ISO 25178-2 from five X-ray computed tomography (XCT) volume measurements from each of four laboratories. To reduce the number of process variables, all participants utilise a Nikon ...