نتایج جستجو برای: scatter correction

تعداد نتایج: 176847  

2007
Christian von Savigny Charles Robert Mark Weber John P. Burrows

SCIAMACHY limb-scatter measurements allow the continuous mapping of noctilucent clouds (NLCs) as well as the retrieval of NLC particle sizes since 2002. Longterm measurements of NLC particle sizes require high instrument stability or an accurate knowledge of the changing calibration parameters. For the NLC measurements we employ measurements in SCIAMACHY channel 1, whose transmission decreased ...

Journal: :Physics in medicine and biology 2009
Xuping Zhu Georges El Fakhri

(86)Y is a PET agent that could be used as an ideal surrogate to allow personalized dosimetry in (90)Y radionuclide therapy. However, (86)Y also emits cascade gamma rays. We have developed a Monte Carlo program based on SimSET (Simulation System for Emission Tomography) to model cascade gamma rays in PET imaging. The new simulation was validated with the GATE simulation package. Agreements with...

Journal: :Physics in medicine and biology 2015
Mootaz Eldib Jason Bini Philip M Robson Claudia Calcagno David D Faul Charalampos Tsoumpas Zahi A Fayad

The purpose of the study was to evaluate the effect of attenuation of MR coils on quantitative carotid PET/MR exams. Additionally, an automated attenuation correction method for flexible carotid MR coils was developed and evaluated. The attenuation of the carotid coil was measured by imaging a uniform water phantom injected with 37 MBq of 18F-FDG in a combined PET/MR scanner for 24 min with and...

Journal: :Physics in medicine and biology 2011
Kyung Sang Kim Jong Chul Ye

Accurate scatter correction is especially important for high-resolution 3D positron emission tomographies (PETs) such as high-resolution research tomograph (HRRT) due to large scatter fraction in the data. To address this problem, a fully 3D iterative scatter-corrected ordered subset expectation maximization (OSEM) in which a 3D single scatter simulation (SSS) is alternatively performed with a ...

Journal: :IEEE journal of biomedical and health informatics 2014
Kyung Sang Kim Young-Don Son Zang-Hee Cho Jong Beom Ra Jong Chul Ye

Scatter correction is very important in 3-D PET reconstruction due to a large scatter contribution in measurements. Currently, one of the most popular methods is the so-called single scatter simulation (SSS), which considers single Compton scattering contributions from many randomly distributed scatter points. The SSS enables a fast calculation of scattering with a relatively high accuracy; how...

Journal: :Medical physics 2010
Taly Gilat Schmidt

PURPOSE Energy-resolved CT has the potential to improve the contrast-to-noise ratio (CNR) through optimal weighting of photons detected in energy bins. In general, optimal weighting gives higher weight to the lower energy photons that contain the most contrast information. However, low-energy photons are generally most corrupted by scatter and spectrum tailing, an effect caused by the limited e...

Mansour Zabihzadeh Zahra Farzanegan

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید