نتایج جستجو برای: slab head phantom

تعداد نتایج: 193829  

Background: Prediction of the absorbed dose in irradiated volume plays an important role in the outcome of radiotherapy. Application of small fields for radiotherapy of thorax makes the dose calculation process inaccurate due to the existence of electronic disequilibrium and intrinsic deficiencies in dose calculation algorithms. To study the lung absorbed dose in radiotherapy with smal...

Journal: :Medical engineering & physics 2012
Matteo Gatto Gianluca Memoli Adam Shaw Neelaksh Sadhoo Pierre Gelat Russell A Harris

A neonatal head phantom, comprising of an ellipsoidal geometry and including a circular aperture for simulating the fontanel was designed and fabricated, in order to allow an objective assessment of thermal rise in tissues during trans-cranial ultrasonic scanning of pre-term neonates. The precise position of a series of thermocouples was determined on the basis of finite-element analysis, which...

Journal: :iranian journal of nuclear medicine 2003
abbas takavar mohammad eftekhari davood beiki mohsen saghari n mostaghim

spect detects γ-rays from administered radiopharmaceutical within the patient body. γ-rays pass through different tissues before reaching detectors and are attenuated. attenuation can cause artifacts; therefore different methods are used to minimize attenuation effects. in our study efficacy of chang method was evaluated for attenuation purpose, using a custom made heart phantom. due to differe...

Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...

Asghar Hadadi, Maryam Dehghanpour Reza Molazadeh Somayeh Gholami,

Introduction: In radiation therapy with high-energy photon beams (E > 7 MeV) neutrons are generated mainly in LINACs head thorough (γ, n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the protocol TG-34, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in...

Journal: :iranian journal of medical physics 0
tayeb allahverdi pourfallah biochemistry and biophysics dept., faculty of medicine, mazandaran university of medical sciences, sari, iran

introduction polymer gel dosimeters offer a practical solution to 3d dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. in this study, egsnrc calculated and pagat polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of gamma knife in homogeneous and inhomogeneous phantoms were compared with eac...

Journal: :JNMA; journal of the Nepal Medical Association 2013
Gopal Prasad Gyawali Bishnu Pokharel Rohit Kumar Pokharel

Anterior dislocation of the elbow joint is a rare entity and is usually associated with injuries to surrounding bony and soft tissues. Simple dislocation of the joint is managed conservatively. An eight years old girl had traumatic anterior dislocation of the elbow joint with intact distal neurovascular status. X-rays showed no associated bony injury. Close reductions failed. Per operative find...

2016
Shou-Kai Chen Xiaoyue Zhang

Abstract: The seepage control system of a high Concrete Face Rock-Fill Dam (CFRD) may have anti-seepage deficiencies during both construction and operation. In order to solve these, the three-dimensional Finite Element Method (FEM) model was built based on dam body filling, anti-seepage system, defect location and bedrock distribution. The seepage field simulation and computation were carried o...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2004
P Rodrigues A Trindade L Peralta C Alves A Chaves M C Lopes

In this paper, we present a novel implementation of a dose calculation application, based on the GEANT4 Monte Carlo toolkit. Validation studies were performed with an homogeneous water phantom and an Alderson-Rando anthropomorphic phantom both irradiated with high-energy photon beams produced by a clinical linear accelerator. As input, this tool requires computer tomography images for automatic...

Journal: :Physics in medicine and biology 2007
Frédéric Noo Stefan Hoppe Frank Dennerlein Günter Lauritsch Joachim Hornegger

In computed tomography, analytical fan-beam (FB) and cone-beam (CB) image reconstruction often involves a view-dependent data differentiation. The implementation of this differentiation step is critical in terms of resolution and image quality. In this work, we present a new differentiation scheme that is robust to changes in the data acquisition geometry and to coarse view sampling. Our scheme...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید