نتایج جستجو برای: taper constant
تعداد نتایج: 221061 فیلتر نتایج به سال:
We report an ultra-sensitive and robust fluorescence sensor made by using a biconical taper with a waist diameter of 720 nm for both excitation and fluorescence collection. To enhance the stability of the fluorescence sensor, the biconical taper has been embedded in a 125 µm wide microchannel with a detection length of 2.5 cm. Investigated by measuring the fluorescence intensity of rhodamine 6G...
Development of efficient and sensitive motion transducers for arrays of nanoelectromechanical systems (NEMS) is important for fundamental research as well as for technological applications. Here, we report a single-wire nanomechanical transducer interface, which relies upon near-field optomechanical interactions. This multiplexed transducer interface comes in the form of a single-mode fiber tap...
Many metal joint failures have been associated with adverse local tissue reactions due to the response of the body to wear debris and corrosion products, released from the bearing surfaces or the taper interfaces. The oxide film on the CoCrMo plays an important role in the electrochemical behaviour, however, there is a lack of quantitative data on the structure and distribution of oxides follow...
Cladded multimode fiber optic tapers are proposed as chemical sensors using evanescent wave absorption. There is no need to strip the cladding; therefore, fabrication is easy and the taper is mechanically stronger than the taper without cladding. The transmission property and evanescent wave absorption are modeled using ray theory and wave theory, respectively. Effects of some parameters on the...
Modularity at the head-neck junction of the femoral component in THA became popular as a design feature with advantages of decreasing implant inventory and allowing adjustment of leg length, offset, and soft tissue balancing through different head options. The introduction of a new modular interface to femoral stems that were previously monoblock, or nonmodular, comes with the potential for cor...
Dissociation of a Morse taper arthroplasty is an uncommon occurrence, especially in the shoulder, reported in only one publication in the English literature.1 In response to reported dissociations of Morse taper modular humeral components, Blevins et al. identified conditions that would interfere with the Morse taper interface strength. The relevant cases were reported only in a single componen...
Because cone outer segments (COS) are now known to be continually renewed, I reexamined COS morphogenesis in retinas of Xenopus tadpoles (prepared by standard histologic techniques and viewed by light and electron microscopy) to clarify how COS incorporate new membrane. I observed that developing COS underwent an unexpected shape change: they were always conical, but their taper (width divided ...
Aging incurs aortic stiffening and dilation, but these changes are less pronounced in peripheral arteries, resulting in stiffness and geometry gradients influencing progression of the forward and reflected pressure waves. Because premature arterial aging is observed in ESRD, we determined the respective roles of stiffness and aortic geometry gradients in 73 controls and 156 patients on hemodial...
BACKGROUND The purpose of this study was to investigate the stability of dual-taper modular implants following impaction forces delivered at varying locations as measured by the distraction forces required to disassemble the components. METHODS Distraction of the head-neck and neck-stem (NS) tapers of dual-taper modular implants with 0°, 8°, and 15° neck angles were measured utilizing a custo...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید