نتایج جستجو برای: three phase four wire distribution grid

تعداد نتایج: 2821150  

2016
Chakphed Madtharad Suttichai Premrudeepreechacharn

This paper presents the design of neural networks compared with the conventional technique, a hysteresis controller for active power filter for three-phase four-wire electric system. A particular three-layer neural network structure is studied in some detail. Simulation and experimental results of the active power filter with both controllers are also presented to verify the feasibility of such...

2012
Ajay Kumar Maurya Yogesh K Chauhan

Abstract—in this paper a concept of generalized theory of instantaneous imaginary power is proposed for a three-phase four-wire system. Unlike instantaneous reactive power theory in which a complex mathematical transformation is used for controlling action of shunt active power filters. The proposed control strategy is simple and further to reduced its complexity the line current vector is deco...

2014
MARYAM ALIBEIK Maryam Alibeik

Alibeik, Maryam. MSECE, Purdue University, August 2014. Different Configurations of Microgrids and Power Converters. Major Professor: Dr. Euzeli dos Santos Jr. This thesis proposes a two-phase microgrid system with voltages in quadrature. The two-phase microgrid system presents the following advantages: 1) constant power through the power line at balanced condition; 2) two voltages available by...

2013

In a balanced three phase system, only harmonics of positive sequence(7 th , 13 th ,..etc) and negative sequence (5 th , 11 th ,…etc) are produced. However, the harmonic currents produced by single phase non-linear loads like switch-mode power supplies in computer which are connected between phase to neutral injects third order zero sequence harmonics (3 rd ,9 th ,15 th …etc) (Mehmet et al 2008...

2013
Junsheng Jiao

Abstract. The paper presents a compensating system for the harmonics and the reactive power using active power filter in three-phase and four-wire systems. The conventional active power filters have been designed based on the p-q theory. However, these types of the filter can only compensate for the reactive power for the load and the detection result is not accurate if the three-phase voltage ...

2012
Yash Pal A. Swarup B. Singh

In this paper, a simplified control algorithm based on unit vector template generation (UVTG) is proposed for a stardelta supported three-phase four-wire (3P-4W) unified power quality conditioner (UPQC) topology for the improvement of different power quality problems. Different topologies reported in literature for 3P-4W UPQC use active compensation for the mitigation of source neutral current ...

2011
M. Bhanu Siva M. R. P Reddy

The topology and control of three-phase 4-wire DSTATCOM consisting of a operating flexibility in the DSTATCOM consisting of a operating flexibly in the voltage or current control mode. In the voltage control DSTATCOM topology includes three single-phase voltage source converters connected in parallel. The proposed DSTATCOM provides the voltage regulation of power factor correction along with ha...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید