Arterial oxygen saturation (SaO(2)) and partial arterial pressure of carbon dioxide (PaCO(2)) are important respiratory parameters in critically ill neonates. A sensor combining a pulse oximeter with the Stow-Severinghaus electrode, required for the measurement of peripheral oxygen saturation (SpO(2)) and transcutaneous partial pressure of carbon dioxide (PtcCO(2)), respectively, has been recen...
BACKGROUND The therapeutic value of transcutaneous electrical stimulation of the genioglossus muscle in patients with obstructive sleep apnea (OSA) to reduce sleep-disordered breathing is unclear. METHODS Contraction of the genioglossus muscles during transcutaneous stimulation was investigated using ultrasonography in 11 healthy subjects (seven men, mean [SD] age 30 [6] years; BMI, 24.2 [3.5...
[Purpose] This study aimed to examine the effects of a combined intervention consisting of massage therapy and transcutaneous electrical nerve stimulation on gastrocnemius muscle fatigue, assessing whether the intervention improved muscle tone, stiffness, and muscle contraction. [Subjects and Methods] The subjects were 20 healthy males in their 20s who were equally divided into a transcutaneous...
Transcutaneous estimation of arterial carbon dioxide in intensive care. Which electrode temperature?
Transcutaneous and arterial carbon dioxide were measured simultaneously in 57 children (age range 10 days to 14.3 years) undergoing intensive care. All were haemodynamically stable at the time of study. Mean calibration time with 5 and 10% carbon dioxide was 43 (range 38-58) minutes and mean arterialisation time was 10.5 (range 3-30) minutes. Duplicate hourly arterial samples over a four hour p...
INTRODUCTION Bariatric surgery has become increasingly more recommended for the treatment of morbidly obese individuals for whom it is possible to identify co-morbidities other than alterations in pulmonary function. The objective of this study was to evaluate the effects of conventional chest physiotherapy (CCP) and of conventional physiotherapy associated with transcutaneous electrical diaphr...
Transcutaneous glucose measurement would provide the ability to obtain frequent measurements without the pain and risk of infection associated with obtaining a blood sample and eliminates the need for reagents. Because of these potential benefits, a large effort is being made within the academic and industrial research communities to develop alternative rapid and easily manageable analysis meth...
[Purpose] This study aimed to clarify the immediate effects of a combined transcutaneous electrical nerve stimulation and stretching protocol. [Subjects] Fifteen healthy young males volunteered to participate in this study. The inclusion criterion was a straight leg raising range of motion of less than 70 degrees. [Methods] Subjects performed two protocols: 1) stretching (S group) of the medial...
Background: Transcutaneous bilirubin measurement (TcB) is widely used in term babies, but its effectiveness as well the suitable site for preterm babies still debated. Aim and Objective: To compare diagnostic accuracy of different transcutaneous sites with serum total neonate. Methods: This prospective comparative study was carried out special care baby unit at Alwahda teaching hospital-Derna-L...