نتایج جستجو برای: transient mode

تعداد نتایج: 347099  

Journal: :IEEE open journal of power electronics 2022

This paper addresses the transient stability of grid-forming (GFM) inverters when transitioning from islanded to grid-connected mode. It is revealed that reconnection GFM main grid can be equivalent a step change active power reference, whose impact closely related with local load, reference inverter, and short-circuit ratio (SCR) grid. Such disturbance may cause lose synchronism To avoid loss ...

2010
Jooyoung Kim Jaeheung Park Salina A Chowdhury Manho Lim

The dynamics of the CN‒-ligated ferric cytochrome c (CytcCN) in D2O at 283 K following Q-band photoexcitation at 575 nm was observed using femtosecond time-resolved vibrational spectroscopy. The equilibrium vibrational spectrum of the CN stretching mode of CytcCN shows two overlapping bands: one main band (82%) at 2122 cm‒1 with 23 cm‒1 full width at half maximum (fwhm) and the other band (18%)...

Journal: :Electrical Engineering 2023

Abstract The increasingly popular inverter distributed generation in microgrids is leading to changes system fault characteristics. behaviors of are closely related the control mode. Here, a photovoltaic power supply constant mode enters low-voltage ride-through state when there microgrid. output current phase analyzed, and local protection method based on difference feeder positive-sequence pr...

Journal: :iranian journal of medical physics 0
mahboobeh alamolhoda msc student, medical physics dept., tarbiat modares university, tehran, iran manijhe mokhtari-dizaji professor, medical physics dept., tarbiat modares university, tehran, iran amir hoshang barati assistant professor, medical physics dept., kurdistan medical sciences university, kurdistan, iran

introduction: transient cavitations induced by low frequency irradiation of ultrasound can be used to treat tumors. previous studies in in-vitro experiments have shown that induced cavitation by dual or multiple frequencies of ultrasound is greater than induced cavitation by single frequency irradiation. in this study, we compared and evaluated the treatment effects of dual frequency irradiatio...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شهید چمران اهواز 1393

آنچه به نام ضربه قوچ در شبکه های خط لوله شناخته می شود، شرایط گذرایی است که ممکن است به علت تغییرات سریع در شبکه ها، راه اندازی یا متوقف شدن پمپ ها و تغییر بار مصرفی توربین ها رخ دهد. در این حالت اغتشاشات وارده با سرعت صوت به صورت موج فشاری مثبت یا منفی در سیستم حرکت کرده و به علت تنش برشی دیواره مستهلک می شود. مقایسه نتایج میدانی و نظری نشان داده است که، مدل اصطکاکی ماندگار و شبه ماندگار به پ...

2001
S. Dewan R. Holmes K. Reiniger F. Voelker J. Zeng

This paper describes a four quadrant, 250kW(550V, 450A) switch-mode, zero current soft switching (ZCS) power converter for a 1.4 GeV beam transfer line magnet. The ZCS technique is the preferred approach for the high power switch-mode converters employing Insolated Gate Bipolar Transistors (IGBT) to reduce switching losses and EMI. This switch-mode power converter topology has been selected bec...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید