نتایج جستجو برای: based oxygen sensor
تعداد نتایج: 3221964 فیلتر نتایج به سال:
INTRODUCTION Recently developed prototypes of zirconium dioxide and NASICON-based micro solid-state electrolyte oxygen (O2) and carbon dioxide (CO2) sensors were tested for their potential suitability in rebreathers. The O2 sensor has a quasi-indefinite lifetime, whilst that of the CO2 sensor is approximately 700 h. This is a preliminary report of a new technological application. METHODS The ...
Today, clinicians often do diagnosis and classification of diseases based on information collected from several physiological sensor signals. However, sensor signal could easily be vulnerable to uncertain noises or interferences and due to large individual variations sensitivity to different physiological sensors could also vary. Therefore, multiple sensor signal fusion is valuable to provide m...
BACKGROUND The use of non-aqueous organic media is becoming increasingly important in many biotechnological applications in order to achieve process intensification. Such media can be used, for example, to directly extract poorly water-soluble toxic products from fermentations. Likewise many biological reactions require the supply of oxygen, most normally from air. However, reliable online meas...
This work presents model-based strategies for on-board catalyst monitoring and fault detection using a simplified catalyst oxygen storage and reversible deactivation model. The performance of the catalyst is inferred from the error between the post-catalyst exhaust gas oxygen sensor measurement and the model predicted value. Each of these strategies is based on the use of some test statistic th...
Clinical EPR spectroscopy is emerging as an important modality, with the potential to be used in standard clinical practice to determine the extent of hypoxia in tissues and whether hypoxic tissues respond to breathing enriched oxygen during therapy. Oximetry can provide important information useful for prognosis and to improve patient outcomes. EPR oximetry has many potential advantages over o...
Objective(s): Today, there is an urgent need for improved sensor materials for drug sensing and effective monitoring and interventions in this area are highly required to struggle drug abuse. The present study aimed to synthesize a thioguanine-responsive sensor based on a nanocomposite consisting of AuNP-grafted light- and temperature-responsive poly butylmethacrylate-co-acrylamide-co-methacryl...
A novel signal amplification strategy for quartz crystal microbalance (QCM) based on catalytic gas generation was developed to construct an ultrasensitive immunosensor for the detection of proteins (immunoglobulin G, IgG, used as a model). A catalase modified immunoparticle was prepared to form a sandwich-type immunocomplex with the IgG and anti-IgG antibodies that were immobilized on the QCM s...
In this study, a slow-responding chemo-optical sensor for dissolved oxygen (DO) integrated into a 96-well plate was developed. The slow response time ensures that the measured oxygen value does not change much during plate transport to the microplate reader. The sensor therefore permits at-line DO measurement of microbial cultures. Moreover, it eliminates the necessity of individual optical mea...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید