In this paper an endovascular measurement system used for intraoperative cerebral blood flow monitoring is described. The system is based on a Volcano ComboMap Pressure and Flow System extended with analogue-to-digital converter and PC laptop. A series of measurements performed in patients with cerebrovascular pathologies allows us to introduce “velocity–pressure” and “flow rate–energy flow rat...
Citation: Tan O, Konduru R, Zhang X, Sadda SR, Huang D. Dual-angle protocol for Doppler optical coherence tomography to improve retinal blood flow measurement. Tran Vis Sci Tech. 2014;3(4):6, http:// tvstjournal.org/doi/full/10.1167/tvst. 3.4.6, doi:10.1167/tvst.3.4.6 Purpose: To compare the performance of two different multiple-scan protocols for total retinal blood flow (TRBF) measurement usi...
Measurements of blood flow by three different makes of thermodilution cardiac output computer in an artificial circulation were analysed by linear regression against absolute flow measured by timed blood volume collection. For each computer the horizontal distance between the 95% confidence limits for a single prediction was calculated at a standard flow rate of 5 litres per minute. This measur...
A non-invasive glucose measurement system based on the method of metabolic heat conformation (MHC) is presented in this paper. This system consists of three temperature sensors, two humidity sensors, an infrared sensor and an optical measurement device. The glucose level can be deduced from the quantity of heat dissipation, blood flow rate of local tissue and degree of blood oxygen saturation. ...
The viability of dental pulp depends largely on regional blood flow, as in other organs. Measurement of absolute pulpal blood flow (PBF) and comparisons with blood flow in other organs allow the prediction of microvascular regulation in dental pulp. In previous studies, PBF was measured in dogs mainly with radioactive microspheres. However, this established technique is inaccessible to many inv...
131 DOI: 10.5963/BER0203002 Development of a Miniaturized Fiber-optic LDV Sensor for Local Blood Velocity Measurement Local Velocity and Flow Profile Measurement of Pulsatile Blood Flow Modeled in Humans Shimpei Kohri, Tsutomu Tajikawa, Kenkichi Ohba Department of Medical Engineering, Aino University 4-5-4, Higashiohda, Ibaraki city, Osaka 567-0012 Japan Department of Mechanical Engineering, Ka...
Cerebral blood flow was measured by xenon-133 washout in 13 patients 6-46 hours after being resuscitated from cardiac arrest. Patients regaining consciousness had relatively normal cerebral blood flow before regaining consciousness, but all patients who died without regaining consciousness had increased cerebral blood flow that appeared within 24 hours after resuscitation (except in one patient...
Photodynamic therapy (PDT) requires oxygen to cause cellular and vascular tumor damage. Tissue oxygen concentration, in turn, is influenced by blood flow and blood oxygenation. Real-time clinical measurement of these hemodynamic quantities, however, is rare. This paper reports the development and application of a probe, combining diffuse reflectance spectroscopy (DRS) for measurement of tumor b...
Evaluation of antidecubitus mattresses is to a large extent based on interface pressure and pressure distribution measurements. These measurements do not give an answer to the effect on the tissue microcirculation cause by the external loading. A better and more direct parameter on the properties’ of the mattress would be to measure blood flow in the tissue under loading. This paper presents a ...
Implanted optical fibers and laser-Doppler flow measurement techniques were used for the sequential measurement of regional renal blood flow in conscious rats to determine the effects of an increase of daily NaCl intake on the renal cortical blood flow and blood flow to the outer and inner medulla. Cortical blood flow was increased significantly (32%) by the second day when NaCl intake was incr...