نتایج جستجو برای: cooling load

تعداد نتایج: 200733  

2007
Youming Chen Xiangqian Li Quan Zhang Jeffrey D. Spitler Dan Fisher

Conduction transfer functions (CTFs) are widely used to calculate conduction heat transfer in building cooling load and energy calculations. They can conveniently fit into any load and energy calculation techniques to perform conduction calculations. There are three methods: the Laplace transform (LP) method, the state-space (SS) method and the frequency-domain regression (FDR) method to calcul...

2009
Zhongzhu Qiu Tintai Chow Peng Li Chunying Li Jianxing Ren Wenhuan Wang

The mathematic models for thermal, and PV solar power inserted in the ESP-r, which is the integrating building energy and environment simulation tool, were verified with the measured da ta. Using the verified model, the energy performance of an office building, equipped toward the south with conventional absorptive single facade or unventilated double PV facade or outward ventilated double PV f...

Journal: :international journal of advanced design and manufacturing technology 0
hamid safari masoud fasihbeygi

in this paper, we are going to improve the energy efficiency of an industrial c 3 mr base load lng plant by changing its refrigerant components and its mole fractions in liquefaction and subcooling cycles based on the cooling curves generated in the main liquefaction and subcooling heat exchangers. later on, selection features of the elements will be discussed. first, non-optimized c 3 mr plant...

Barat Ghobadian Behdad Shadidi Hossein Haji Agha Alizade

In internal combustion engines, only about a third of the total fuel input energy is converted into useful work. If the energy rejected into the cooling system and the exhaust gases could be recovered instead and put into useful work, fuel economy would have been substantially improved. The main aim of this research paper was to evaluate the effects of the hybrid nano-catalyst containing ce...

2017
Yin Bi Yugang Wang Xiaoli Ma Xudong Zhao

Information technology (IT) has brought significant changes in people’s lives. As an important part of the IT industry, data centres (DCs) have been rapidly growing in both the number and size over the past 40 years. Around 30% to 40% of electricity consumption in DCs is used for space cooling, thus leading to very inefficient DC operation. To identify ways to reduce the energy consumption for ...

2015
Samuel Salinas-Almaguer Abril Angulo-Sherman Francisco Javier Sierra-Valdez Hilda Mercado-Uribe Boris Rubinsky

High hydrostatic pressure (HHP) affects the structure, metabolism and survival of micro-organisms including bacteria. For this reason HHP is a promising treatment in the food industry. The aim of this work is to evaluate the effect of high pressure, under isochoric cooling conditions, on Escherichia coli, where such high pressure develops due to the fact water cannot expand. We combine survival...

2015
M. Gayatri

As the number of transistors increases with new generation of microprocessor chips, the power draw and heat load to dissipate during operation increases. As a result of increasing the heat loads and heat fluxes the Conventional cooling technologies such as fan, heat sinks are unable to absorb and heat transfer excess heat dissipated by these new microprocessor. So, new technologies are needed t...

Journal: :Journal of the Korea Society For Power System Engineering 2014

Journal: :The Journal of prosthetic dentistry 2012
John P Tan Dalene Sederstrom Joshua R Polansky Edward A McLaren Shane N White

STATEMENT OF PROBLEM Porcelain fused to zirconia prostheses are widely used. However, porcelain chipping, spalling, fracture, and delamination are common clinical problems. Residual stresses of thermal origin have received attention, but clear data and firing guidelines remain absent. PURPOSE The purpose of this study was to measure the influence of heating and cooling protocols on the streng...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید