نتایج جستجو برای: defibrillator
تعداد نتایج: 8427 فیلتر نتایج به سال:
Introduction In cases of patients who have contraindications to transvenous pacing leads but still require pacing, surgically placed epicardial pacing leads are often used. If such a patient warranted implantable cardioverter-defibrillator (ICD), a subcutaneous ICD (S-ICD) system would be ideal from the standpoint of avoidance of transvenous leads, but devicedevice interaction with the epicardi...
We report a case of persistent left superior vena cava (PLSVC) incidentally recognized during the implantation of a cardioverter-defibrillator. PLSVC is the most common venous anomaly of the thorax and drains into the right atrium. There are a lot of publications reporting success of pacemaker or defibrillator lead implantations via PLSVC. In this article we present the technique of approaching...
St. Jude Medical (SJM) has recently announced a global medical device advisory that was also communicated by US FDA in a letter dated 11th October 2016 [1]. The advisory related to the risk of premature battery depletion in some of the implantable cardioverter-defibrillator (ICD) and Cardiac Resynchronization Therapy e Defibrillator (CRT-D) devices manufactured by SJM prior to 23rd May 2015. Th...
A 32-year-old man with Duchenne muscular dystrophy (DMD) was admitted to the hospital because of worsening dyspnea and general fatigue. He had received medication therapy for cardiomyopathy with heart failure and home mechanical ventilation for respiratory failure. An electrocardiogram on admission showed intermittent third-degree atrioventricular block. Echocardiography showed global mild left...
Long QT syndrome (LQTS) can present with syncope and seizure-like activity in the setting of torsades de pointes (TdP) with hemodynamic instability. Electrolyte abnormalities and medications can predispose to TdP in the setting of latent LQTS. An implantable cardioverter defibrillator (ICD) is needed if patients with TdP continue to be symptomatic despite medical treatment. We report a case of ...
A promising therapy for ventricular fibrillation--a life-threatening cardiac arrhythmia--is implantation of an automatic defibrillator. A critical component of such a device is the system that detects the presence of ventricular fibrillation. Automatic systems for detecting ventricular fibrillation have been tested with arrhythmias produced by electric shocks in normal canine hearts, but have n...
Only four cases of tricuspid stenosis related to endocardial pacemaker leads have been reported. Two further cases associated with perforation of a tricuspid valve leaflet by a pacemaker lead are presented: a 46 year old woman and a 60 year old man. It is possible that tricuspid valve disease related to endocardial pacemaker and non-thoracotomy defibrillator leads is underrecognized. Diagnosis ...
The subcutaneous implantable cardioverter-defibrillator (S-ICD) is a safe alternative to transvenous ICD. We describe a submuscular S-ICD placement technique in a severely obese with an oversized chest. Submuscular configuration allows optimal system positioning and impendence values warranting a safe and effective shock transmission. This technique is safe and improves patients comfort.
AIMS The number of patients with cardiac implantable electronic devices (permanent pacemakers and implantable cardioverter defibrillators) undergoing radiotherapy treatment is increasing. The aims of this audit were to establish current UK practice regarding the management of patients with implanted cardiac devices undergoing radiotherapy and to compare this practice with current 'gold standard...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید