نتایج جستجو برای: delivery rooms

تعداد نتایج: 215991  

2006
Hyung Jin Kim Soo Young Kim Won Hee Seo Byung Min Choi Young Yoo Kee Hyoung Lee Baik Lin Eun Hai Joong Kim

During a four-week period, four healthy term newborn infants born at a regional maternity hospital in Korea developed late-onset neonatal group B Streptococcus (GBS) infections, after being discharged from the same nursery. More than 10 days after their discharge, all of the infants developed fever, lethargy, and poor feeding behavior, and were subsequently admitted to the Korea University Medi...

Journal: :BMJ 2004
Jeffrey D Horbar Joseph H Carpenter Jeffrey Buzas Roger F Soll Gautham Suresh Michael B Bracken Laura C Leviton Paul E Plsek John C Sinclair

OBJECTIVE To test a multifaceted collaborative quality improvement intervention designed to promote evidence based surfactant treatment for preterm infants of 23-29 weeks' gestation. DESIGN Cluster randomised controlled trial. SETTING AND PARTICIPANTS 114 neonatal intensive care units (which treated 6039 infants of 23-29 weeks gestation born in 2001). MAIN OUTCOME MEASURES Process of care...

Journal: :Neonatology 2015
Nariae Baik Berndt Urlesberger Bernhard Schwaberger Thomas Freidl Georg M Schmölzer Gerhard Pichler

BACKGROUND The fetal-to-neonatal transition is a complex process that includes changes in cardiac and respiratory systems. OBJECTIVE The aim of this study is to review the different methods of cardiocirculatory monitoring during the immediate neonatal transition period. METHODS A systematic search of PubMed and Ovid Embase was performed using the following terms: infant, newborn, newborn in...

Journal: :Archives of disease in childhood. Fetal and neonatal edition 2015
Kenji Hishikawa Keiji Goishi Takeo Fujiwara Masao Kaneshige Yushi Ito Haruhiko Sago

OBJECTIVE The Japan Resuscitation Council (JRC) Guidelines 2010 for neonatal resuscitation introduced continuous positive airway pressure (CPAP) in delivery room. The present study evaluated the effect of CPAP for pulmonary air leak at term birth. DESIGN, SETTING AND PATIENTS This retrospective single-centre study used the data of term neonates who were born without major congenital anomalies...

2015
Mario Rüdiger Nicole Braun Jacob Aranda Marta Aguar Renate Bergert Alica Bystricka Gabriel Dimitriou Khaled El-Atawi Sascha Ifflaender Philipp Jung Katarina Matasova Violeta Ojinaga Zita Petruskeviciene Claudia Roll Jens Schwindt Burkhard Simma Nanette Staal Gloria Valencia Maria Gabriela Vasconcellos Maie Veinla Máximo Vento Benedikt Weber Anke Wendt Sule Yigit Heinz Zotter Helmut Küster

BACKGROUND Since an objective description is essential to determine infant's postnatal condition and efficacy of interventions, two scores were suggested in the past but weren't tested yet: The Specified-Apgar uses the 5 items of the conventional Apgar score; however describes the condition regardless of gestational age (GA) or resuscitative interventions. The Expanded-Apgar measures interventi...

Journal: :Frontiers in pediatrics 2016
Jeroen J. van Vonderen Henriëtte A. van Zanten Kim Schilleman Stuart B. Hooper Marcus J. Kitchen Ruben S. G. M. Witlox Arjan B. te Pas

Neonatal resuscitation is one of the most frequently performed procedures, and it is often successful if the ventilation applied is adequate. Over the last decade, interest in seeking objectivity in evaluating the infant's condition at birth or the adequacy and effect of the interventions applied has markedly increased. Clinical parameters such as heart rate, color, and chest excursions are dif...

2016
Hosein Dalili Mahdi Sheikh Amir Kamal Hardani Firouzeh Nili Mamak Shariat Fatemeh Nayeri Umberto Simeoni

OBJECTIVES Assessing the value of the Combined-Apgar score in predicting neonatal mortality and morbidity compared to the Conventional-Apgar. METHODS This prospective cohort study evaluated 942 neonates (166 very preterm, 233 near term, and 543 term) admitted to a tertiary referral hospital. At 1- and 5-minutes after delivery, the Conventional and Combined Apgar scores were recorded. The neon...

Journal: :The Medical journal of Malaysia 2015
K F Ng P Choo U Paramasivam S A Soelar

INTRODUCTION T-piece resuscitator (TPR) has many advantages compared to self-inflating bag (SIB). Early Continuous Positive Airway Pressure (CPAP) during newborn resuscitation (NR) with TPR at delivery can reduce intubation rate. METHODS We speculated that the intubation rate at delivery room was high because SIB had always been used during NR and this can be improved with TPR. Intubation rat...

Journal: :Archives of disease in childhood. Fetal and neonatal edition 2012
Thomas M Berger Martina A Steurer Andreas Woerner Philipp Meyer-Schiffer Mark Adams

BACKGROUND The publication of Swiss guidelines for the care of infants at the limit of viability (22-25 completed weeks) was followed by increased survival rates in the more mature infants (25 completed weeks). At the same time, considerable centre-to-centre (CTC) differences were noted. OBJECTIVES To examine the trend of survival rates of borderline viable infants over a 10-year-period and t...

2014

OBJECTIVE: This study was done to compare 2 techniques of pulse oximeter sensor application during neonatal resuscitation for faster signal detection. METHODS: Sensor to infant first (STIF) and then to oximeter was compared with sensor to oximeter first (STOF) and then to infant in $28 weeks gestations. The primary outcome was time from completion of sensor application to reliable signal, defin...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید