نتایج جستجو برای: dosimetry linear accelerator add on mlc recommissioning

تعداد نتایج: 8622156  

ژورنال: سنجش و ایمنی پرتو 2016

Knowing patient exact dose during radiological activities is considered as one of the main principles to decrease radiation-induced dangers which are not really necessary and affect a great deal of people. In this respect, in recent years many extensive studies have been done on types of photodiodes and production of X-ray detectors using semiconductor elements. Since these elements are not ver...

Journal: :iranian journal of radiation research 0
f. bouzarjomehri department of medical physics, shahid sadoghi university of medical sciences, yazd, iran t. bayat department of medical physics, centre for education and training, zanjan, iran m.h. dashti r department of physiology, shahid sadoghi university of medical sciences, yazd, iran j. ghisari department of physics, yazd university, yazd, iran n. abdoli department of architecture, yazd university, yazd, iran

abstract  introduction: recently uses of medium and high energy x-rays has been increased in iran and radiotherapy centers along with a variety of accelerators have been installed in some provinces. in the other hand there is no sufficient skill in designing and making radiotherapy treatment rooms. this study was conducted to evaluate the efficacy of different mixtures of barite concrete for sh...

Journal: :Radiation Oncology (London, England) 2009
Q Jackie Wu Zhiheng Wang John P Kirkpatrick Zheng Chang Jeffrey J Meyer Mei Lu Calvin Huntzinger Fang-Fang Yin

BACKGROUND This study evaluated the dosimetric impact of various treatment techniques as well as collimator leaf width (2.5 vs 5 mm) for three groups of tumors -- spine tumors, brain tumors abutting the brainstem, and liver tumors. These lesions often present challenges in maximizing dose to target volumes without exceeding critical organ tolerance. Specifically, this study evaluated the dosime...

Journal: :Zeitschrift fur medizinische Physik 2010
Jörg Wulff Johannes T Heverhagen Heiko Karle Klemens Zink

Current dosimetry protocols require geometrical reference conditions for the determination of absorbed dose in external radiotherapy. Whenever these geometrical conditions cannot be maintained the application of additional corrections becomes necessary, in principle. The current DIN6800-2 protocol includes a corresponding factor k(NR), but numerical values are lacking and no definite informatio...

Journal: :Physics in medicine and biology 2011
Tuathan P O'Shea Yuanyuan Ge Mark J Foley Bruce A Faddegon

An extendable x-ray multi-leaf collimator (eMLC) is investigated for collimation of electron beams on a linear accelerator. The conventional method of collimation using an electron applicator is impractical for conformal, modulated and mixed beam therapy techniques. An eMLC would allow faster, more complex treatments with potential for reduction in dose to organs-at-risk and critical structures...

2013
Tamader Y. AL-Rammah H. I. Al-Mohammed F. H. Mahyoub

Metal oxide semiconductor field effect transistor (MOSFET) detectors have recently been introduced to radiation therapy. However, the response of these detectors is known to vary with dose rate. Therefore, it is important to evaluate how much variation between the treatment prescribed dose and the dose that is actually delivered to the patient using high-energy photon or electron beams under co...

Journal: :Review of Scientific Instruments 1955

Journal: :Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology 2012
Nasrollah Jabbari Amir Hoshang Barati Leili Rahmatnezhad

AIM The aim of this work was to develop multiple-source models for electron beams of the NEPTUN 10PC medical linear accelerator using the BEAMDP computer code. BACKGROUND One of the most accurate techniques of radiotherapy dose calculation is the Monte Carlo (MC) simulation of radiation transport, which requires detailed information of the beam in the form of a phase-space file. The computing...

2018
Bin Cai S. Murty Goddu Sridhar Yaddanapudi Douglas Caruthers Jie Wen Camille Noel Sasa Mutic Baozhou Sun

Normalize the response of electronic portal imaging device (EPID) is the first step toward an EPID-based standardization of Linear Accelerator (linac) dosimetry quality assurance. In this study, we described an approach to generate two-dimensional (2D) pixel sensitivity maps (PSM) for EPIDs response normalization utilizing an alternative beam and dark-field (ABDF) image acquisition technique an...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید