نتایج جستجو برای: electrode engineering
تعداد نتایج: 325461 فیلتر نتایج به سال:
A carbon nanocomposite electrode has been designed by incorporation of montmorillonite nanoclayinto the carbon ionic liquid electrode for the electrochemical determination of amitriptiline . The surface ofthe proposed electrode was characterized by scanning electron microscopy. The presence of ionic liquid asa binder is believed to be responsible for the electrocatalytic activity of the propose...
We used an effective electrochemical sensor for the determination of imipramine at pH 7.2 using a carbon nanocomposite electrode. The electrode has been designed by incorporation of montmorillonite nanoclay into the carbon ionic liquid electrode. The high sensitivity of 1.714 μA (μM)-1, two linear calibration ranges of 0.1–2 μM and 2-40 μM, and detection limit of 19 nM were achieved. The relati...
In this study, first,diffusible hydrogen of cellulosic electrode E8010-P1 and low hydrogen electrode E8018-G was measured by mercury displacement method according to ISO3690. Then,the effect of preheating and post-heating on the sensitivity to hydrogen inducedcold cracking in welding of 18mm API5L X70 steel with these electrodes was investigated according to ISO17642-2. The results of visual in...
The effect or temperature on the behavior of Cu(II) Mr electrode based on bis(N-sahcylidenc-3.3'-4iaminodiphenyl) sulfune(BSDDS) was studied. This electrode showed a good Nemstian response in the temperaturerange of 20-50 C. Also, the behavior of the synthesized electrode was inngigated in the mixed solvents'ethanol+water" and "dioxane +water'.
Here, a simple, quick, Low cost and sensitive Potentiometric method is described for tramadol hydrochloride measurement using .PVC membrane electrode based on neutral ligand (E)-N'-(1-(2-hydroxyphenyl)ethylidene)benzohydrazid. Besides, effect of various parameters like ionic additives, membrane solvent and pH on the Potentiometric response of the electrode are investigated. The best electrode p...
In this research, a coated graphite electrode was constructed for determination of Mg2+ in pharmaceutical supplements. The designed sensor demonstrates an ideal Nernstian slope (30.1 mV. Decade-1) over a wide concentration range (1×10-6- 1×10-1 Mol L-1). The selectivity of the sensor was evaluated over 16 different cations by matched potential method and no serious interference was observed fro...
A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...
In article number 2001201, Zhen Li, Yunhui Huang, and co-workers present an ultrathin, lightweight, highly conductive Bi2Te2.7Se0.3 interlayer on the separator surface that can not only enhance capacity utilization of sulfur electrode, but also improve cycling stability due to strong interaction between polysulfides intrinsic antisite defects. This work proposes a defect engineering strategy ac...
Suspensions of electrocatalytic platinum nanoparticles with radii as small as 78.9 ± 3.5 nm that are functionalised with DNA only in one region have been created using templated electrodeposition. The integrity of the bound DNA following nanoparticle desorption from the electrode is demonstrated by detecting attomolar concentrations of DNA without the need for molecular, e.g., PCR or NASBA, amp...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید