نتایج جستجو برای: electron beam therapy

تعداد نتایج: 1041352  

Journal: :Journal of Vacuum Science & Technology B, Nanotechnology and Microelectronics: Materials, Processing, Measurement, and Phenomena 2011

Journal: :journal of biomedical physics and engineering 0
m ebrahimi loushab a a mowlavi physics department, faculty of sciences, ferdowsi university of mashhad, mashhad, iran m h hadizadeh physics department, school of sciences, hakim sabzevari university, sabzevar, iran 3ictp, associate federation, medicalسازمان اصلی تایید شده: دانشگاه فردوسی (ferdowsi university) r izadi 1physics department, faculty of sciences, ferdowsi university of mashhad, mashhad, iranسازمان اصلی تایید شده: دانشگاه حکیم سبزواری (hakim sabzevari university) s b jia physics department, university of bojnord, bojnord, iranسازمان اصلی تایید شده: دانشگاه فردوسی (ferdowsi university)

normal 0 false false false en-us x-none fa microsoftinternetexplorer4 background: in radiation therapy with ion beams, lateral distributions of absorbed dose in the tissue are important. heavy ion therapy, such as carbon-ion therapy, is a novel technique of high-precision external radiotherapy which has advantages over proton therapy in terms of dose locality and biological effectiveness. metho...

2015
Hamid Reza Baghani Seyed Mahmoud Reza Aghamiri Seyed Rabi Mahdavi Mohammad Esmail Akbari Hamid Reza Mirzaei

The specific design of the mobile dedicated intraoperative radiotherapy (IORT) accelerators and different electron beam collimation system can change the dosimetric characteristics of electron beam with respect to the conventional accelerators. The aim of this study is to measure and compare the dosimetric characteristics of electron beam produced by intraoperative and conventional radiotherapy...

Journal: :Physical review. E, Statistical, nonlinear, and soft matter physics 2009
J P Palastro T M Antonsen

Copropagation of a laser pulse and a relativistic electron beam in a corrugated plasma channel has been proposed for the direct laser acceleration of electrons [Palastro, Phys. Rev. E 77, 036405 (2008)]. The corrugated plasma channel allows for the guiding of laser pulses composed of subluminal spatial harmonics. Phase matching between the electron beam and the spatial harmonics results in acce...

The effect of evaporation rate on structural, morphological and optical properties of electron beam evaporated CdS thin films have been investigated. CdS thin film deposited by electron beam evaporation method in 12nm/min and 60nm/min evaporation rates on glass substrates. X-ray diffraction, scanning electron microscopy, UV-Vis-NIR spectroscopy and Atomic Force Microscopy were used to character...

Journal: :iranian journal of radiation research 0
k. adinehvand borujerd islamic azad university, borujerd, iran m.h. zahmatkesh novin radiation medicine institute, tehran, iran m.r aghamiri division of radiation medicine, shahid beheshti university, tehran, iran sh. akhlaghpour department of radiology, tehran university of medical sciences, tehran, iran s. bagheri novin radiation medicine institute, tehran, iran

background: the purpose of this study was to evaluate the dependency of magica polymer gel dosimeter response (r2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. materials and methods: the sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modality. a cali...

Abdolazim Sedighi Alireza Khoshghadam Mohammad Hadi Gholami, Mohammad Mohammadi,

Introduction: Because of importance of impact of the Source to Surface Distance (SSD) in determining of monitor unit for electron-therapy, it is essential to know the Virtual Source Position (VSP) for electron beam for a linear therapeutic accelerator for each energy and field size. , especially using the Khan method (photo distance squared method) And compare the results with...

2001
R. Li J. J. Bisognano

A linac-ring collision scheme was considered in recent proposals of electron-gold colliders (eRHIC) and polarized-electron light-ion colliders (EPIC). The advantages of using an energy-recovered linac for the electron beam is that it avoids the limitation of beam-beam tune shift inherent in a storage ring, pertains good beam quality and easy manipulation of polarization. However, the interactio...

Journal: :European journal of radiology 2008
Scott D Oves Kenneth R Hogstrom Kyungmin Ham Erno Sajo Joseph P Dugas

The purpose of this study was to compare dose measurements using ion chamber and radiochromic film dosimetry for a 35-keV synchrotron beam useful for Auger electron therapy. A 1.3-GeV electron beam, transported through a 3-pole superconducting wiggler magnet, produced a polychromatic photon beam from which a 35-keV beam (3.3 mm Al HVL) was selected using a monochromator. A 2.8 cm x 2.5 cm field...

Journal: :Physics in medicine and biology 2000
I Orion A B Rosenfeld F A Dilmanian F Telang B Ren Y Namito

Microbeam therapy is established as a general concept for brain tumour treatment. A synchrotron based x-ray source was chosen for experimental research into microbeam therapy, and therefore new simulations were essential for investigating the therapy parameters with a proper description of the synchrotron radiation characteristics. To design therapy parameters for tumour treatments, the newly u...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید