نتایج جستجو برای: flicker svc statcom

تعداد نتایج: 5979  

2007
Akiko Takeda

A binary linear classification method, CGS method, was recently proposed by Gotoh and Takeda. The classification model was developed by introducing a risk measure known as the conditional value-at-risk (β-CVaR). CVaR minimization for the margin distribution leads to CGS problem, equivalent to ν-SVC of Schölkopf et al. in the convex case and Extended ν-SVC of Perez-Cruz et al. in the nonconvex c...

Journal: :Circulation. Arrhythmia and electrophysiology 2013
Shinsuke Miyazaki Hiroshi Taniguchi Yuki Komatsu Takashi Uchiyama Shigeki Kusa Hiroaki Nakamura Hitoshi Hachiya Kenzo Hirao Yoshito Iesaka

BACKGROUND Superior vena cava (SVC) is an infrequent yet an important source of atrial fibrillation. The clinical impact of ATP injection on arrhythmogenic SVC has not been evaluated. METHODS AND RESULTS A total of 43 patients (59±11 years; men, 32) who underwent ATP test for arrhythmogenic SVC after the electric isolation at either initial procedure or repeat procedure were included. Pulmona...

2015
S. Pushpavalli

Due to the rapid growth of non-linear loads, such as power electronic control equipments and Electric arc furnace (EAF) power quality problems such as harmonics and voltage flicker are introduced in the power system. It occurs because of the time-varying and nonlinear behaviour of the Load. Arc furnaces are used in industries for induction heating and welding. Hence an Electric arc furnace mode...

Journal: :Circulation 2002
Yi-Jen Chen Yao-Chang Chen Hung-I Yeh Cheng-I Lin Shih-Ann Chen

BACKGROUND The superior vena cava (SVC) has been proved to be a focal point in the initiation of paroxysmal atrial fibrillation. The autonomic nervous system plays an important role in the genesis of atrial fibrillation. However, the arrhythmogenic potentials of SVC and its responses to autonomic agents are not clear. The purpose of this study was to isolate single SVC cardiomyocytes and to inv...

Journal: :Circulation journal : official journal of the Japanese Circulation Society 2015
Kensuke Ihara Takeshi Sasaki Yasuhiro Shirai Susumu Tao Shingo Maeda Mihoko Kawabata Tetsuo Sasano Yasuhiro Yokoyama Mitsuaki Isobe Kenzo Hirao

BACKGROUND The purpose of this study was to clarify the relation between atrial defibrillation threshold (ADFT) for internal cardioversion (IC) and arrhythmogenicity of the superior vena cava (SVC). METHODS AND RESULTS A total of 159 consecutive patients (139 male, age 59.9±10.3 years) who underwent radiofrequency catheter ablation of atrial fibrillation (AF) were assessed. IC was performed i...

2011
Komolafe

This paper presents the mathematical steady-state modelling of Static Synchronous Compensator (STATCOM), which is the most widely used member of Flexible Alternating Current Transmission Systems (FACTS). STATCOM Power Injection Model (PIM), derived from one voltage source representation, is presented and analyzed in detailed. A program, Flexible Alternating Current Transmission Systems Power Fl...

2013
Alireza Zohoori Ahad Kazemi Rouhollah Shafaie

Grid disturbances, especially grid faults, have very unfavorable effect on the performance of wind turbine based Doubly Fed Induction Generator (DFIG). In this study active and reactive powers control of DFIG with STATCOM has been carried out to improve Fault Ride Through (FRT) capability of a wind turbine. In order to excel improvement of the DFIG behavior under grid fault disturbances, an opt...

2016
R. Ilango T. Sree Renga Raja

Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to locate the fault in a transmission line compensated with STATCOM with simple calculations. The proposed protection method considers the STATCOM injected/absorbed current to correct the...

2010
Abdolaziz Ashrafian Mehrdad Rostami

In this paper, a method based on continuous wavelet transform is suggested for calculation of flicker power. The flicker power can be utilized to identify the flicker direction to a flicker source with respect to a monitoring point. In our proposed method, using continuous Gaussian wavelet transform, pure flicker waveforms are extracted from the measured voltage and current signals. The flicker...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه زنجان 1390

به دلیل اهمیت مسائل زیست محیطی و همچنین کمبود سوخت های فسیلی متداول برای تامین انرژی، استفاده از انرژی های تجدید پذیر در سراسر جهان مخصوصا در دهه گذشته بیشتر مورد توجه قرار گرفته و از بین این منابع، انرژی باد یکی از مهمترین انرژی هایی بوده که استفاده از آن رشد بسیار سریعی داشته است. همراه با توسعه روز افزون نیروگاه های بادی در شبکه قدرت و اتصال این نیروگاه های کوچک به سیستم های به هم پیوسته قد...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید