Journal: :Physics in medicine and biology 2011
Andrew Kelly Nicholas Hardcastle Peter Metcalfe Dean Cutajar Alexandra Quinn Kerwyn Foo Michael Cardoso Sheree Barlin Anatoly Rosenfeld

Curative breast radiotherapy typically leaves patients with varying degrees of cosmetic damage. One problem interfering with cosmetically acceptable breast radiotherapy is the external contour for large pendulous breasts which often results in high doses to skin folds. Thermoplastic casts are often employed to secure the breasts to maintain setup reproducibility and limit the presence of skin f...

Journal: :Precision radiation oncology 2023

A newly developed GafchromicTM EBT4 film model was released recently. According to the vendor-stated specifications, this new maintains major features of its more recent predecessor, EBT3, but has a great improvement in signal-to-noise ratio (SNR). The purpose study fully characterize by testing dose response dependence on beam energy using clinical photon and electron beams validating SNR. In ...

2017
Yinghui Li Lixin Chen Jinhan Zhu Xiaowei Liu

PURPOSE The aim of this study was to combine a set of methods for use of radiochromic film dosimetry, including calibration, correction for lateral effects and a proposed triple-channel analysis. These methods can be applied to GAFCHROMIC EBT3 film dosimetry for radiation field analysis and verification of IMRT plans. METHODS A single-film exposure was used to achieve dose calibration, and th...

Journal: :iranian journal of medical physics 0
micaeil mollazadeh m.sc. student in medical physics, medical physics and engineering dept., tehran university of medical sciences, tehran, iran. mahmood allahverdi associate professor, medical physics and engineering dept., tehran university of medical sciences, tehran, iran. tayyeb allahverdi pourfallah assistant professor, biochemistry and biophysics dept., mazandaran university of medical sciences, sari, iran. nader riahi alam associate professor, medical physics and engineering dept., tehran university of medical sciences, tehran, iran. mohammadreza ay associate professor, medical physics and engineering dept., tehran university of medical sciences, tehran, iran.

introduction: gafchromic ebt films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (tpss). their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. this study was designed to evaluate the dosimetric parameters of...

Journal: :Dento maxillo facial radiology 2013
A Al-Okshi M Nilsson A Petersson M Wiese C Lindh

OBJECTIVES To demonstrate the feasibility of GafChromic(®) XR-QA2 (ISP Corp., Wayne, NJ) as a dosemeter when performing measurements of the effective dose from three cone beam CT (CBCT) units and to compare the doses from examinations of three common dental clinical situations. A second aim was to compare the radiation doses for three digital panoramic units with the doses for the CBCT units. ...

2016
Hideharu Miura Shuichi Ozawa Fumika Hosono Naoki Sumida Toshiya Okazue Kiyoshi Yamada Yasushi Nagata

Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT-XD films have been designed for optimal performance in the 40-4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose-response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high-do...

2014
Mara Severgnini Mario de Denaro Marina Bortul Cristiana Vidali Aulo Beorchia

Intraoperative electron radiation therapy (IOERT) cannot usually benefit, as conventional external radiotherapy, from software systems of treatment planning based on computed tomography and from common dose verify procedures. For this reason, in vivo film dosimetry (IVFD) proves to be an effective methodology to evaluate the actual radiation dose delivered to the target. A practical method for ...

Journal: :Medical physics 2012
David Lewis Andre Micke Xiang Yu Maria F Chan

PURPOSE Radiochromic film provides dose measurement at high spatial resolution, but often is not preferred for routine evaluation of patient-specific intensity modulated radiation therapy (IMRT) plans owing to ease-of-use factors. The authors have established an efficient protocol that combines calibration and measurement in a single scan and enables measurement results to be obtained in less t...