2005
Peter Gehrke Marco Degidi Andre Spanel Günter Dhom Adriano Piattelli

Although initial considerations in implant dentistry have claimed that the process of osseointegration requires on average an undisturbed healing of three months in the mandible and six months in the maxilla 1-3, an increasing interest has been noticed with regard to early and immediate loading of implants to expedite the restorative outcome. Donath et al. reported that load exerted at the impl...

2014
Xi Ding Sheng-Hui Liao Xing-Hao Zhu Hui-Ming Wang

OBJECTIVE The study was to investigate the impact of orthotropic material on the biomechanics of dental implant, based on a detailed mandible with high geometric and mechanical similarity. MATERIALS AND METHODS Multiple data sources were used to elaborate detailed biological structures and implant CAD models. In addition, an extended orthotropic material assignment methodology based on harmon...

Journal: :Journal of biomechanics 1993
H Weinans R Huiskes H J Grootenboer

Connective soft tissues at the interface between implants and bone, such as in human joint replacements, can endanger the stability of the implant fixation. The potential of an implant to generate interface bone resorption and form soft tissue depends on many variables, including mechanical ones. These mechanical factors can be expressed in terms of relative motions between bone and implant at ...

2017
Nils-Claudius Gellrich Björn Rahlf Rüdiger Zimmerer Philipp-Cornelius Pott Majeed Rana

BACKGROUND Every endosseous dental implant is dependent on an adequate amount and quality of peri-implant hard and soft tissues and their fully functional interaction. The dental implant could fail in cases of insufficient bone and soft tissues or due to a violation of the soft to hard tissues to implant shoulder interface with arising of a secondary bone loss. METHOD To overcome this biologi...

Journal: :The International journal of oral & maxillofacial implants 1999
F Iamoni G Rasperini P Trisi M Simion

The aim of this study was to compare the characteristics of the bone-to-implant interface of hydroxyapatite-coated and non-coated commercially pure titanium threaded implants after different periods of healing in humans. To eliminate possible variations of the results from differences in bone quality and in surgical techniques used in the different test and control sites, only one half of each ...

Journal: :European cells & materials 2008
V A Stadelmann O Gauthier A Terrier J M Bouler D P Pioletti

It is a clinical challenge to obtain a sufficient orthopaedic implant fixation in weak osteoporotic bone. When the primary implant fixation is poor, micromotions occur at the bone-implant interface, activating osteoclasts, which leads to implant loosening. Bisphosphonate can be used to prevent the osteoclastic response, but when administered systemically its bioavailability is low and the time ...

2018
Philippe Moewis Sara Checa Ines Kutzner Hagen Hommel Georg N Duda

Mechanical and kinematical aligning techniques are the usual positioning methods during total knee arthroplasty. However, alteration of the physiological joint line and unbalanced medio-lateral load distribution are considered disadvantages in the mechanical and kinematical techniques, respectively. The aim of this study was to analyse the influence of the joint line on the strain and stress di...

2017
Anders Petersson

The resonance frequency analysis (RFA) technique is widely used for stability assessments of dental implants. The technique makes use of a transducer peg, which is attached to the implant and excited over a range of frequencies by electro-magnetic waves to measure the resonance frequency (RF) of the peg. The underlying RF in Hz is then translated to an Implant Stability Quotient (ISQ) on a scal...

2013
T. Rack S. Zabler A. Rack H. Riesemeier K. Nelson

The implant-abutment connection of a two-piece dental implant depicts a complex micro-mechanical behavior: a micro-gap is evident at the implant-abutment interface, even in the virgin state. Its width varies when external mechanical load is applied. High resolution synchrotron-based radiography in combination with hard X-ray phase contrast to image this gap and estimate its size is deployed. Th...

2012
Osamu Komiyama Frank Lobbezoo Antoon De Laat Takashi Iida Tsuyoshi Kitagawa Hiroshi Murakami Takao Kato Misao Kawara

There is general agreement that excessive stress to the bone-implant interface may result in implant overload and failure. Early failure of the implant due to excessive loading occurs shortly after uncovering the implant. Excess load on a final restoration after successful implant integration can result in physical failure of the implant structure. Many clinicians believe that overload of denta...