نتایج جستجو برای: mixed refrigerant cycle
تعداد نتایج: 491177 فیلتر نتایج به سال:
The rotary compressor accumulator with pre-charged oil has already been developed and the concept published.[I] Compared to the conventional accumulator, the new accumulator differentiates itself from the conventional one in that the new accumulator is pre-charged with a pre-determined amount of oil. It offers advantages as a conventional accumulator attached to rotary compressor. This paper no...
Knowledge of the solubility characteristics of an oiVrefrigerant mixture is important when analyzing the lubrication system behavior in refrigerant compressors since the solubility significantly affects the viscosity of the mixture. For an operating compressor, the lubricant is a mixture of oil and refrigerant and the viscosity of the mixture is a strong function of the refrigerant concentratio...
Solubility (vapor pressure) , viscosity and density have been experimentally determined for thirty-five potential refrigeration working fluids. Properties for low refrigerant concentration mixtures (0, 10, 20 and 30 weight percent refrigerant) were determined over the temperature range 0 to IOO•C (32 to 212"F) or to the critical temperature of the refrigerant, and pressure range 0 to 3,500 kPa ...
This paper presents an analytical evaluation of isobutane (R600a), propane (R290), R134a, R22, R410A, and R32 in a vapor compression system used for comfort cooling applications. The evaluation method was based on a system simulation model that was complimented with an evolutionary computation module for the optimization of refrigerant circuitries in the evaporator and condenser. The evaluation...
In a research project of EADS Airbus and the TUHH a system simulation of a cooling system is to be realized, using the refrigerant carbondioxid (CO2). The simulation models of the cooling cycle are created using Modelica and the thermohydraulic model library ThermoFlow. Modelica and the model library operate since spring 2000. The project will be finished untill the end of 2002. For the structu...
Mathematical models have been popularly applied to study the compression processes of superheated refrigerant vapor in compressors. As to the case when refrigerant enters a compressor cylinder in the state of liquid and vapor mixture, however, the availability of fundamental studies is very limited. -A mathematical model is presented to simulate the compression processes of two-phase saturated ...
The use of nanoparticles along with the conventional refrigerant in a vapor compression cycle is relatively new idea, where nano-refrigerants are found to have improved thermo-physical properties over refrigerants. Nano-refrigerant combination improve performance refrigeration process. In this study, developed nanofluid from agricultural source (rice husk) was applied domestic refrigerator and ...
This study proposes a procedure for a risk analysis for leakages of flammable refrigerants into a poorly ventilated three-dimensional space. It also presents several test cases of risk analyses on flammability and ignitions to a leaked refrigerant. Concentration of a leaked flammable refrigerant at a leakage window, Cin, is determined by mass balance, providing information on the capacity of an...
introduction pulmonary vein (pv) isolation is considered as a key to atrial fibrillation (af) treatment. cryoballoon ablation is an effective therapy for pv isolation for af with minimal side effects and was approved by the us food and drug administration (fda) several years ago. successful isolation of pvs during cryoablation depends on the balloon temperature and helps in early identification...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید